Quick Reference Guide

13 SLOT-13 N/A N/A Not Present N/A
14 SLOT-14 PowerEdgeM60
0
ON Present 33
15 SLOT-15 N/A N/A Not Present N/A
16 SLOT-16 N/A Extension(8) N/A N/A
Switch Module Fan Request Table
<IO Name> <Name> <Type> <Presence> <Fan Request%>
Switch-1 Dell Ethernet
Pass-Through
Gigabit
Ethernet
Present 30
Switch-2 Dell
PowerConnect
M6220
Gigabit
Ethernet
Present 30
Switch-3 N/A None Not Present N/A
Switch-4 N/A None Not Present N/A
Switch-5 N/A None Not Present N/A
Switch-6 N/A None Not Present N/A
getioinfo
Description Displays general information about the I/O modules on the chassis.
This subcommand is applicable only for CMC.
To use this subcommand, you must have CMC Login User privilege.
NOTE:
The fabric type may be any supported I/O fabric type, such as Ethernet, Fiber Channel,
and Infiniband.
Synopsis
racadm getioinfo [-m <module>] [-s]
Input
-m <
module
> — Specifies the module or device.
<module>
must be switch - <n>, where n
= 1–6
-s — use to display stack information.
Example
racadm getioinfo
<IO> <Name> <Type> <Presence
>
<POST> <Power> <Role>
switch-1 Dell
Ethernet
Gigabit
Ethernet
Present OK ON Master
51