Release Notes

Issue Description
DSM-24193 Storage Manager might lock a Storage Manager account after half the number of log in attempts
than allowed by the account lockout threshold.
Workaround: Increase the account lockout threshold to double the desired amount.
DSM-21139 Attempting to update a Data Collector installed on a Windows Server using the System Updates
option in the Unisphere causes an error. The System Updates option is used only for the Storage
Manager Virtual Appliance.
Workaround: None
DSM-20806 The Unisphere displays primary Data Collector functions for remote Data Collectors. Initiating
those functions might cause replication using that remote Data Collector to fail.
Workaround: None
DSM-20769 The Generate Fault Domain Conguration option in the Congure Fibre Channel Fault Tolerance
wizard is not available in the Unisphere.
Workaround: Use the Storage Manager Client to generate the default Fibre Channel fault domain.
DSM-20746 When attempting to reconnect a Storage Center connected using a host name without a sux,
the Unisphere might fail to connect reporting that the host name is incorrect.
Workaround: Reconnect the Storage Center using the full host name with the sux.
DSM-19661 After restarting the Virtual Appliance, the Unisphere displays the login screen before the Virtual
Appliance is fully up and ready for logins.
Workaround: Wait for the Virtual Appliance to fully start up before logging in.
DSM-18844 Creating multiple volumes with Group or Volume QoS Proles from a server in the Unisphere fails
to set the QoS Proles on the volumes.
Workaround: Set the QoS Prole on the volumes after creating the volumes.
DSM-18409 Storage Manager does not show an error if it fails to connect to a Data Collector database after
changing the data source. Instead, the Change Data Source wizard returns to the rst page.
Workaround: Correct the connection failure with the Data Collector database then attempt to
change the data source again.
DSM-17754 After changing the source Storage Center when creating a volume, the volume folder does not
change to a folder on the new Storage Center.
Workaround: Change the volume folder after changing the Storage Center.
DSM-16444 After creating a rule for a Snapshot Prole, the Unisphere uses UTC time instead of the time zone
set on the Storage Center. This issue can cause the start time of the rule to be o by multiple
hours.
Workaround: Create the rule and adjust for the time dierence or create the rule using the
Storage Manager Client.
DSM-16373, DSM-16368 The Unisphere does not show the progress of a Data Collector data source change.
Workaround: Use the Dell Storage Manager Client to change the data source of a Data Collector.
DSM-16267 The Unisphere does not require the user to specify a new IP address when adding a port to a
VLAN. This issue causes the operation to fail.
Workaround: Use the Storage Manager Client.
DSM-16075 The Unisphere does not enable Allow Storage Prole Selection in the User Preferences dialog by
default.
Workaround: Enable Allow Storage Prole Selection.