Release Notes

Issue Description
DSM-16062 An error occurs after switching SNMP from SNMP v3 to SNMP v1/v2 using the Unisphere.
Workaround: Use the Storage Manager Client.
DSM-15789 While migrating a Data Collector, the summary page in the Unisphere incorrectly states that the
database is an internal database and that there is not an administrator user.
Workaround: None
DSM-15748 The Est. Full column in the Storage Centers table displays the incorrect time. It shows AM in
place of PM and PM in place of AM.
Workaround: None
DSM-15151 After switching the display language from English to Chinese, the Unisphere still displays English.
Workaround: None
DSM-15130 Resizing the window on the Unisphere causes buttons and information to overlap.
Workaround: Refresh the page in the Storage Manager Client.
Open Issues Related to Cross-Platform Replication
The following open issues are related to cross-platform replication between Storage Centers and PS Series groups.
Issue Description
DSM-28871 Attempting to recreate an iSCSI connection in a cross-platform replication after deleting the iSCSI
connection fails.
Workaround: Contact Dell Technical Support.
DSM-26371 Storage Manager might incorrectly display the progress of a cross-platform replication as 100%
after pausing a cross-platform replication at 50% then restarting the lead controller on the PS
Group.
Workaround: Resume the replication.
DSM-25944 Storage Manager displays an incorrect name for the operating system of a Remote PS Group.
Workaround: None
DSM-25697 After attempting to congure an iSCSI connection from a Storage Center to a PS Group that is
already setup, then selecting another PS Group that is not setup,Storage Manager attempts to
setup a connection to the PS Group that was selected rst.
Workaround: Close the Congure iSCSI Connection then reopen it and select the correct PS
Group.
DSM-25282 If a remote PS Group fails to respond 90 seconds after creating an iSCSI connection the
connection was still created successfully. However, the Congure iSCSI Connection wizard
remains open. Clicking Finish again attempts to create the same connection again and fails.
Workaround: Do not click Finish. Close the window then refresh the Storage Manager Client.
DSM-24885 The Create QoS dialog box appears behind the Create Replication dialog box when replicating
multiple volumes without a QoS denition created.
Workaround: Create a QoS denition before replicating volumes or move the Create Replication
dialog box to access the Create QoS dialog box.
DSM-23428 Storage Manager might freeze when activating disaster recovery on a large number of volumes.
Workaround: Close the Storage Manager Client then reopen it.
17