Administrator Guide

Command syntax
secli (list temp sensors | listtemperaturesensors | lts) (-a=<(SAS WWID |
AdapterIndex)> -enc=<(WWN | EnclIndex)> [-outputformat<SupportedOutputFormats>]
| -enc=<WWN> [-outputformat=<SupportedOutputFormats>] | [-h])
Parameters
Table 15. List temperature sensors
Parameter Description
-a
Specify the adapter used for the command. This is either SAS
WWID or AdapterIndex.
-enc
Specify the enclosure used for the command. This is either
WWN or EnclIndex.
-h
Provides more information about the command, description,
and usage.
-outputformat
You can specify the following output formats: xml or json.
Command examples
list temp sensors -a = 1 -enc = 500a123456789012
list temp sensors -a = 1 -enc = 0
list temp sensors -enc = 500a123456789012 -outputformat = xml
List voltage sensors
Description
This command lists the voltage sensors accessible from the specified enclosure.
Command syntax
secli (list voltage sensors | listvoltagesensors | lvs) (-a=<(SAS WWID |
AdapterIndex)> -enc=<(WWN | EnclIndex)> [-
outputformat=<SupportedOutputFormats>] | -enc=<WWN> [-
outputformat=<SupportedOutputFormats>] | [-h])
Parameters
Table 16. List voltage sensors
Parameter Description
-a
Specify the adapter used for the command. This
can be either SAS WWID or AdapterIndex.
-enc
Specify the enclosure used for the command. This
is either WWN or EnclIndex.
-h
Provides more information about the command,
description, and usage.
28