EMC AX4-5 Series Integrated Management Software Version 02.23.050.5.709 Release Notes P/N 300-005-724 REV A10 May 11, 2010 These release notes contain supplemental information about EMC® CLARiiON® AX4-5 (or AX4-5F), AX4-5i, AX4-5SC (or AX4-5FSC), AX4-5SCi (or AX4-5iSC), AX4-5F8 (or AX4-5FX), AX4-5SCF4 (or AX4-5FSCX) Integrated Management Software version 02.23.050.5.709. This document uses the following terms: - Server refers to a server or host that sends data to or receives data from the storage system.
Revision history Revision history The following table presents the revision history of this document. 2 Revision Date Description A10 5/11/2010 Patch revision for 02.23.050.5.709; see the “New features and changes” and “Fixed problems” sections for details. A09 11/11/2009 Patch revision for 02.23.050.5.707; see the “New features and changes” and “Fixed problems” sections for details. A08 05/07/2009 Clarified VMware product name in the table in the “Fixed problems” section.
Product description Product description The AX4-5, AX4-5i, AX4-5SC, AX4-5SCi, AX4-5F8, AX4-5SCF4 Integrated Management Software consists of the storage-system and server software below. Storage-system software component ® ® EMC FLARE Operating Environment, which includes - Shared storage control - EMC Navisphere® Express - Snapshot management Version 02.23.050.5.709 Optional software components Expansion tier enabler 01.01.5.
Product description Storage-system software component ™ EMC SnapView admsnap (AIX) SnapView admsnap (HP/UX) SnapView admsnap (Linux) SnapView admsnap (NetWare) SnapView admsnap (Solaris) SnapView admsnap (Win 2003) SnapView admsnap (Win 2008) SnapView admsnap (Windows 2000) EMC PowerPath® for Microsoft Windows PowerPath for Red Hat or SUSE Linux Version See the Admsnap Release Notes for further details See the PowerPath release notes on the AX45 support website* PowerPath for Novell NetWare** PowerPath
Product description When you power up the storage system, each SP boots and executes FLARE OE software. Shared storage control Shared storage control software allows only the server(s) assigned to a virtual disk to access the virtual disk. Navisphere Express EMC Navisphere Express is a storage-system-based management utility for configuring and managing AX4-5 series storage systems.
Product description Navisphere Storage System Initialization Utility The EMC Navisphere Storage System Initialization Utility runs on your management station or attached server. It discovers uninitialized AX4-5 series storage systems, lets you assign IP addresses to the SPs on the same subnet, assign IPs to iSCSI ports for AX4-5i and AX4-5SCI storage systems, and set up security for these storage systems.
New features and changes New features and changes Increased support for Fibre Channel I/O FLARE version 02.23.050.5.707 adds support for AX4-5F8 and AX4-5SCF4, which provide four Fibre Channel ports per storage processor. If you are managing an AX4-5F8 or AX4-5SCF4 storage system, host initiator records will be propagated to all ports on storage processor A and storage processor B.
Environment and system requirements Environment and system requirements This section identifies the minimum environment and system requirements necessary for the AX4-5SC, AX4-5SCi, AX4-5F8, AX4-5SCF4 , AX4-5, and AX4-5i Integrated Management Software components. Storage-system type Minimum hardware requirements AX4-5SC, AX4-5SCi or AX4-5SCF4 • 1 SP • 1 power supply • SATA drives only, in one enclosure • Minimum 4 drives.
Environment and system requirements Solaris client AIX client HP-UX client For a listing of the currently supported versions of these operating systems, refer to Supported Configurations in the “Technical descriptions” section on the AX4-5 support website. PowerPath requirements For PowerPath requirements, refer to the PowerPath release notes on the AX4-5 support website.
Fixed problems Fixed problems This section identifies issues fixed with this version or recent previous versions. Visit the EMC Powerlink® Issue Tracker website at http://Powerlink.EMC.com for the most recent updates and information on previous FLARE versions. Problems fixed in version 02.23.050.5.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment Standby power supply (SPS) cabling status can be incorrectly marked as faulted if an SPS transitions to batteryon-line while being tested. 240286 Frequency of occurrence: Always under a rare set of circumstances Severity: Low Standby power supply (SPS) cabling status can be incorrectly marked as faulted if an SPS transitions to battery-online while being tested.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment When one storage processor is rebooting while LUNs are being trespassed to the peer storage processor, the peer storage processor may bugcheck (0x008000f1) if a trespassing LUN becomes unowned or degraded.
Fixed problems Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment Storage processor bugchecks (0x0000007e) may occur if a host sends commands to a non-existent LUN. 33767086 /355858 33930452/357465 33026284/248994 Frequency of occurrence: Likely under a specific set of circumstances Severity: Critical Storage processor bugchecks (0x0000007e) may occur if a host sends commands to a nonexistent LUN.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 Navisphere Manager On the Setup Page the Restart Managament Server option is not audit logged correctly. 354654 Frequency of occurrence: Always. Severity: Low The username should be included in the audit log entry. KnowledgeBase ID: None Solution (or workaround) Fixed in code Exists in versions: 02.23.050.5.004 02.23.050.5.504 02.23.050.5.505 02.23.050.5.703 02.23.050.5.705 02.23.050.5.
Fixed problems Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 Navisphere Express Secure CLI SP I/O module details show as N/A. 28948480 / 223876 Frequency of occurrence: Rarely under a specific set of circumstances. Severity: Low SP I/O module details show as N/A. KnowledgeBase ID: None Fixed in code Exists in versions: 02.23.050.5.004 02.23.050.5.504 02.23.050.5.505 02.23.050.5.703 02.23.050.5.705 Fixed in version: 02.23.050.5.
Fixed problems 16 Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment When a zone configuration is disabled, storage systems affected by the zone change may experience storage processor bugchecks (0x01901057, 0x000000d1). 28121930/219399 Frequency of occurrence: Rarely under a rare set of circumstances.
Fixed problems Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment When several fabric state changes occur very closely together, a single storage processor bugcheck (0x01944108) may occur. 29979658/228960 Frequency of occurrence: Likely under a rare set of circumstances. Severity: Medium When several fabric state changes occur very closely together, a single storage processor bugcheck (0x01944108) may occur.
Fixed problems Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment An enclosure may be reported as faulted after an LCC is replaced. 231405 Frequency of occurrence: Rarely under a specific set of circumstances. Severity: Medium An enclosure may be reported as faulted after an LCC is replaced. KnowledgeBase ID: None Fixed in code Exists in versions: 02.23.050.5.004 02.23.050.5.504 02.23.050.5.505 02.23.050.5.
Fixed problems Platforms Brief description Symptom details AX4-5SC AX4-5SCi FLARE Operating Environment Storage processor bugchecks (0x00000041) may occur during I/O processing on an AX4-5SC or AX4-5SCi storage system. 25721564/209421 Frequency of occurrence: Rarely under a rare set of circumstances. Severity: Critical Storage processor bugchecks (0x00000041) may occur during I/O processing on an AX4-5SC or AX4-5SCi storage system.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi FLARE Operating Environment Making a LUN snapshot available to a host system while there is a LUN migration in process on the storage system may result in storage processor bugchecks (0xe117b264).
Fixed problems Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi FLARE Operating Environment Hosts attempting to boot their operating system over iSCSI from the storage system may fail. 213662 Frequency of occurrence: Likely under a rare set of circumstances. Severity: Critical Hosts attempting to boot their operating system over iSCSI from the storage system may fail due to too many login sessions.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i FLARE Operating Environment During power maintenance both storage processors may reboot. 25051866/206590 Frequency of occurrence: Likely under a specific set of circumstances. Severity: Critical During power maintenance affecting a switch or host and one-side of a storage system, in rare cases, the host I/O to the failed side may become stuck.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi FLARE Operating Environment The storage system may experience degraded performance when running VMware vSphere 4.0. 218213 Frequency of occurrence: Likely under a specific set of circumstances. Severity: Medium The storage system may experience degraded performance when using the VMware FT feature in VMware vSphere 4.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi Navisphere Express Navisphere Express fails to load and displays The Navisphere Express fails to load and displays The Shared Storage Control Enabler is not installed on the storage system although it is installed. 26024916 / 210915 25473468 / 208845 Frequency of occurrence: Rarely under a specific set of circumstances.
Fixed problems Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi Navisphere Express Continuous calls to getlog will slowly start to degrade management performance. 216483 Frequency of occurrence: Rarely under a specific set of circumstances. Severity: Low Continuous calls to getlog will slowly start to degrade management performance. This is done anytime diagnostic files are created. KnowledgeBase ID: None Fixed in code Exists in versions: 02.23.050.
Fixed problems Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi Navisphere Express A Solaris PowerPath device is displayed in Navisphere Express with the native device name. 182773 Frequency of occurrence: Always under a specific set of circumstances. Severity: Medium The PowerPath device name is not displayed until the device is mounted on Solaris. This happens only in the user interface; The Naviserverutilcli displays the device name properly.
Fixed problems Problems fixed in version 02.23.050.5.504 Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi FLARE Operating Environment RAID 3 LUNs greater than 2 TB are not supported. 184510 Severity: Low Frequency of occurrence: Always This version of software does not support RAID 3 LUNs greater than 2 TB. RAID 3 LUNs greater than 2 TB are now supported. Exists in version: 02.23.050.5.004 Fixed in version: 02.23.050.5.
Fixed problems 28 Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi FLARE Operating Environment Cache is not enabled after SPS misconfiguration is corrected. 184205 Frequency of occurrence: Always under a specific set of circumstances. Severity: Low During initial system setup, if the SPS cabling is misconfigured, an alert occurs and cache is not enabled.
Fixed problems Solution (or workaround) Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi FLARE Operating Environment A Navisphere Express alert is not cleared after an SPS misconfiguration is corrected. 184205 Frequency of occurrence: Always under a specific set of circumstances. Severity: Low After correcting an SPS cabling misconfiguration, the Navisphere Express alert persists until the next time the SPS is tested.
Fixed problems 30 Platforms Brief description Symptom details AX4-5 AX4-5i AX4-5SC AX4-5SCi Navisphere Express Manual registration of an initiator record with the same name but different case of a name already registered automatically results in a Navisphere Express error: An unknown error has occurred while displaying the page.
Known problems and limitations Known problems and limitations This section identifies outstanding issues with this version, and important warnings associated with the connectivity and compatibility of this product. It also provides useful recommendations. Visit the EMC Powerlink® Issue Tracker website at http://Powerlink.EMC.com for the most recent updates and information on previous FLARE versions. Known problems in version 02.23.050.5.
Known problems and limitations 32 Platforms Brief description Symptom details Solution (or workaround) AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment An NDU fails to complete and the storage system returns to normal operation. 186684 Frequency of occurrence: Rarely under a specific set of circumstances Severity: Low An NDU fails to complete. The storage system returns to a normal running state following the failure. Re-attempting the NDU should be successful.
Known problems and limitations Platforms Brief description Symptom details Solution (or workaround) AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 FLARE Operating Environment Single-SP panic occurs when the cache is shutting down. 182007 Frequency of occurrence: Rarely under a specific set of circumstances. Severity: Medium If two drives within the same RAID group experience media errors on the same logical block address, then shutting down the cache can result in a single-SP panic.
Known problems and limitations 34 Platforms Brief description Symptom details Solution (or workaround) AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 Navisphere Express Navisphere Express does not support use of the auto-select encoding option in Internet Explorer (IE). Frequency of occurrence: Always under a specific set of circumstances Severity: Medium Enabling the auto-select encoding option in IE will result in an unreadable character display in localized versions of Navisphere Express.
Known problems and limitations Platforms Brief description Symptom details Solution (or workaround) AX4-5 AX4-5i AX4-5SC AX4-5SCi AX4-5SCF4 AX4-5F8 Navisphere Express Navisphere Express does not give details after an HBA is successfully modified. 203737 Frequency of occurrence: Always under a specific set of circumstances Severity: Low After an HBA record is successfully modified, only the View All Connections link is present. Details of the modified HBA record are not displayed.
Known problems and limitations Navisphere Express with Internet Explorer 7 limitations The default security setting of the Internet Explorer 7 (IE7) browser might interfere with the normal operation of Navisphere Express. To support Navisphere Express with IE7, perform the following steps: 1. In IE7, click the Tools button located in the upper right part of the screen (next to the gear icon) and select Internet Options. 2. Click the Security tab and then click the Custom Level button. 3.
Known problems and limitations 4. In the Untrusted Certificate popup page, click View certificates. The General tab of the Certificate dialog box opens. You should see a note telling you that this certificate is not trusted. 5. Click Install Certificate. The Certificate Import Wizard opens. 6. In the Welcome screen, click Next. 7. In the Certificate Store screen, select the Place all certificates in the following store option. 8.
Known problems and limitations The maximum number of migrations that can be executing at one time is 4. Snapshot configuration limitations Snapshots Maximum number Per storage system 16 Per source virtual disk 1 PowerPath limitations Any PowerPath limitations are described in the PowerPath release notes on the AX4-5 support website.
Technical notes Technical notes This section contains information that will help with the installation, use, and management of the storage system. It provides generic information that applies to all platforms, as well as platform-specific information. Navisphere CLI Navisphere CLI is no longer supported on the AX4-5 series storage systems. Navisphere Secure CLI should be used instead.
Technical notes Notes: This procedure may take 30-60 minutes to complete. During this procedure, you may see some temporary alerts including 0x7428, 0x743a, 0x720f, 0x7403 or 0x7404. After the upgrade completes, all alerts will eventually disappear. An optional second SPS can be added after Step 7. The single SP will not use the SPS so the second SPS is always new when the second SP comes up.
Technical notes Disk module insertion and removal When inserting or removing more than one disk module from a storage system, you must pause between each removal and insertion to allow the storage system to recover. Before inserting or removing the next disk module you should make sure that: A newly inserted disk module's amber light is off and its blue light has returned to a normal state: on or blinking due to I/O in progress.
Technical notes Linux server notes Snapshot management The reboot of the Linux server may be slow if deactivated snapshots exist. Activating the snapshots allows the reboot to complete normally. VMware ESX Server configuration and usage notes See the notes in the “Installation” section.
Documentation Documentation The AX4-5 support website where you accessed these release notes also contains the most up-to-date documents and troubleshooting trees. The AX4-5 Series Documentation CD (P/N 053-001-992) that shipped with the storage system also contains documents and troubleshooting trees for this product; however, they are superceded by those on the AX4-5 support website. The troubleshooting trees on the AX4-5 support website are updated frequently.
Documentation Update to AX4-5 Series - Installing an iSCSI Storage System with a Network Connection to a Windows Server and AX4-5 Series - Installing an iSCSI Storage System with a Direct Connection to a Windows Server Dynamic disks Contrary to what the installation guides say, do not upgrade a disk in an iSCSI storage system to a dynamic disk when writing a digital signature to the disk. Dynamic disks are not supported by the Microsoft iSCSI Software Initiator.
Software media, organization, and files Software media, organization, and files The following table lists the software and documentation media for this product version. Part number 053-001-987 053-001-541 053-001-996 053-001-854 053-001-710 053-001-797 053-001-799 CD-ROM AX4 Series Server Support CD (contains Navisphere CLIs, Navisphere Storage Initialization Utilities, Navisphere Server Utilities and admSnap for all supported host types) PowerPath Netware 3.0.6 CD PowerPath Windows 5.1 & 4.5.
Installation Skip the step on installing software enablers because they are not needed for Navisphere Express. Use Navisphere Express to configure the storage system as follows: 1. Create a hot spare. 2. Create one or more disk pools. 3. Create one or more virtual disks on the disk pools. 4. Assign one or more disks to the ESX Server. Use Navisphere Express to set up Event Notification.
Troubleshooting and getting help Troubleshooting and getting help To troubleshoot problems with your AX4-5SC, AX4-5SCi, AX4-5, AX4-5i, AX4-5F8 or AX4-5SCF4 storage system, use the troubleshooting trees in the “Troubleshoot” section on the AX4-5 support website or the AX4-5 Series Documentation CD. You must use the troubleshooting trees before your service provider will send you a replacement part. To launch the troubleshooting trees, click the Interactive help tool in the “Troubleshoot” section.