0388:Not a valid WCQE code: x<hex cqe_code>
The event code is invalid. This event will be dropped.
Data: None
Severity: Error
Log: LOG_SLI
Action: Ensure that the adapter firmware is current.
0391:Error during rpi post operation
The driver was trying to post pages to the firmware to keep target login information and encountered a failure.
Data: None
Severity: Error
Log: LOG_MBOX, LOG_SLI
Action: Unload and reload the driver.
0393:Error <rc> during rpi post operation
The driver was trying to post pages to the firmware to keep target login information and encountered a failure.
Data: None
Severity: Error
Log: LOG_MBOX, LOG_SLI
Action: Unload and reload the driver.
0395: The mboxq allocation failed
The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA (read link attention) mailbox
command.
Data: None
Severity: Error
Log: LOG_SLI
Action: None required.
0396:The lpfc_dmabuf allocation failed
The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA mailbox command.
Data: None
Severity: Error
Log: LOG_SLI
Action: None required.
0397:The mbuf allocation failed
The asynchronous link event handler could not allocate DMA for the READ_LA mailbox command.
Data: None
Severity: Error
Log: LOG_SLI
Action: None required.
0398 Invalid link fault code: <hex link_fault>
The attempt to read the link attention register returned an unknown value.
Data: None
Severity: Error
Log: LOG_INIT
Action: None required.