Users Guide

Table Of Contents
Broadcom DRVLin-UG128-100
67
Emulex Drivers for Linux User Guide
0448: Adapter failed to init, mbxCmd <mbxCommand> READ_SPARM, mbxStatus <mbxStatus>
Adapter initialization failed when issuing a READ_SPARM mailbox command.
Data: None
Severity: Error
Log: Always
Action: This error could indicate a hardware or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0449: lpfc_%attr attribute cannot be initialized to %d, allowed range is [%min, %max]
The sysfs attribute value written exceeds attribute range.
Data: (1) attribute name (2) value written (3) minimum value (3) maximum value
Severity: Error
Log: Always
Action: Write a value within the supported range.
0450: lpfc_%attr attribute cannot be set to %d, allowed range is [%min, %max]
The sysfs attribute value written exceeds attribute range.
Data: (1) attribute name (2) value written (3) minimum value (3) maximum value
Severity: Error
Log: Always
Action: Write a value within the supported range.
0453: Adapter failed to init, mbxCmd <mbxCommand> READ_CONFIG, mbxStatus <mbxStatus>
Adapter initialization failed when issuing a READ_CONFIG mailbox command.
Data: None
Severity: Error
Log: Always
Action: This error could indicate a hardware or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0456: Adapter failed to issue ASYNCEVT_ENABLE mbox status x%x
The mailbox command to enable an asynchronous event notification failed.
Data: None
Severity: Error
Log: LOG_INIT
Action: Ensure the adapter firmware is current. Reload the driver.
0457: Adapter Hardware Error
The driver received an interrupt indicating a possible hardware issue.
Data: (1) status (2) status1 (3) status2
Severity: Error
Log: Always
Action: This error could indicate a hardware or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0458: Bring adapter online
The FC driver received a request to bring the adapter online. This issue might occur when running lputil.
Data: None
Severity: Warning
Log: LOG_INIT verbose
Action: None required.
Table 8: FC Error Log Messages and Their Descriptions (Continued)