Administrator Guide

CPU Version : Intel I386
Stack Unit Board temperatur : 49 Degree C
Stack Unit Number : 0
Serial Number : Z8FX122P00109
Part Number : 7520057401
Product Revision : H
Version : E9-0-0-23
**************************** Z9000 LEVEL 0 DIAGNOSTICS**************************
+ TEST - 1
PSU [0] STATUS ---> POWER ON
PSU [0] STATUS ---> POWER OK
PSU [0] STATUS ---> PSU OK
Test 1.000 - Psu status monitor test ................................ PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuStatusMonitorTest[96]: ERROR: Getting PSU -1 power status failed..
Test 1.001 - Psu status monitor test ................................ FAIL
Test 1 - Psu status monitor test .................................... FAIL
+ TEST - 2
PSU [0] Voltage Val ---> 12
Test 2.000 - Psu voltage read test .................................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuVoltageReadTest[188]: ERROR: Getting PSU -1 power status failed..
Test 2.001 - Psu voltage read test .................................. FAIL
Test 2 - Psu Voltage Read Test ..................................... FAIL
+ TEST - 3
PSU [0] Temperature ---> 45 Degree Celcius
Test 3.000 - Psu temperature read test .............................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuTemperatureTest[258]: ERROR: Getting PSU -1 power status failed..
Test 3.001 - Psu temperature read test .............................. FAIL
Test 3 - Psu Temperature Test ...................................... FAIL
+ TEST - 4
PSU [0] Fan Speed ---> 17441 RPM
Test 4.000 - Psu Fan Speed Monitor Test ............................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuFanSpeedMonitorTest[378]: ERROR: Getting PSU -1 power status
failed..
Test 4.001 - Psu Fan Speed Monitor Test ............................. FAIL
Test 4 - Psu Fan Speed Monitor Test ................................ FAIL
+ TEST - 5
PSU [0] Source Type --> AC
Test 5.000 - Psu Source type test ................................... PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuSourceTypeTest[517]: ERROR: Getting PSU -1 power status failed..
Test 5.001 - Psu Source type test ................................... FAIL
Test 5 - Psu Source Type Test ...................................... FAIL
+ TEST - 6
PSU [0] Fan FLOW Type Normal (IO --> Rear)
Test 6.000 - Psu Fan module type detect test ........................ PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuFanModuleTypeDetectTest[448]: ERROR: Getting PSU -1 power status
failed.
The following example shows how to run offline diagnostics in Debug mode.
NOTE: Dell Networking highly recommends reloading the system after running the offline
diagnostics in Debug mode.
Dell#diag stack-unit 0 level0 verbose no-reboot
Warning - diagnostic execution will cause multiple link flaps on the peer side
- advisable to shut
912
Z-Series Debugging and Diagnostics