System information

Stacking PowerConnect 10G Switches: M8024-k, 8024, 8024F
52
console(config)#switch 4 renumber 3
The switch will be reset to perform unit renumbering
and the configuration of switch interfaces will be cleared.
Are you sure you want to renumber? (y/n)y
Allow a few minutes for the switch to renumber, then enter the following.
console(config)#do show switch
Management Standby Preconfig Plugged-in Switch Code
SW Status Status Model ID Model ID Status Version
--- ---------- --------- ------------- ------------- ------------- -------
1 Mgmt Sw PC8024 PC8024 OK 4.2.0.1
2 Stack Mbr Oper Stby PC8024F PC8024F OK 4.2.0.1
3 Stack Mbr PC8024F PC8024F OK 4.2.0.1
4 Unassigned PC8024F Not Present 0.0.0.0
The switch that was Unit #4 is now Unit #3. Unit #4 is no longer present. To remove it from the list,
perform the no member command for a second time as shown in Stack Configuration Mode.
console(config)#stack
console(config-stack)#no member 4
console(config-stack)#do show switch
Management Standby Preconfig Plugged-in Switch Code
SW Status Status Model ID Model ID Status Version
--- ---------- --------- ------------- ------------- ------------- -------
1 Mgmt Sw PC8024 PC8024 OK 4.2.0.1
2 Stack Mbr Oper Stby PC8024F PC8024F OK 4.2.0.1
3 Stack Mbr PC8024F PC8024F OK 4.2.0.1
Note: Consult the User Guide for additional stacking information.
Web Interface Method
Since any SFP+ interface on these switches can be used for stacking, be sure to verify exactly which
ports are being used so they are un-cabled and re-routed last.
1. Select System > Stack Management > Stack Port Summary.