Installation manual

Figure 13. Routing Optical Fibres using the Cable Management System
1. Rack unit to be installed only for optical
cables
2. Z9500 switch
NOTE: When the switch operates in the supported temperature range, LR4 optics can be used
only in the upper half of the ports on the switch:
Line card 0 — only in ports 12, 16, 20, 36, 40, 44, 60, 64, 68, 84, 88, 92, 108, 112, 116, 132,
136, and 140.
Line card 1 — only in ports 12, 16, 20, 36, 40, 44, 60, 64, 68, 84, 88, 92, 108, 112, 116, 132,
136, 140, 156, 160, 164, 180, 184, and 188.
Line card 2 — only in ports 12, 16, 20, 36, 40, 44, 60, 64, 68, 84, 88, 92, 108, 112, 116, 132,
136, 140, 156, 160, 164, 180, 184, and 188.
When the switch operates in a reduced ambient temperature, you can use LR4 optics in any
port. See Port Numbering Convention for an illustration that shows port location.
Installing the QSFP+ Optics
The switch has 132 QSFP+ optical ports, which can be used with breakout cables for 528 small form-
factor pluggable plus (SFP+) optical ports.
When the switch operates in the supported temperature range, LR4 optics can be used only in the upper
half of the ports on the switch:
On line card 0: only in ports 12, 16, 20, 36, 40, 44, 60, 64, 68, 84, 88, 92, 108, 112, 116, 132, 136, and
140.
On line card 1: only in ports 12, 16, 20, 36, 40, 44, 60, 64, 68, 84, 88, 92, 108, 112, 116, 132, 136, 140,
156, 160, 164, 180, 184, and 188.
On line card 2: only in ports 12, 16, 20, 36, 40, 44, 60, 64, 68, 84, 88, 92, 108, 112, 116, 132, 136, 140,
156, 160, 164, 180, 184, and 188.
32
Z9500 Installation