Administrator Guide

Fabric Watch Administrator’s Guide 31
53-1002752-01
Setting Fabric Watch custom and default values
5
Setting Fabric Watch custom and default values
Use the following commands to switch between custom and default values. These commands reset
all thresholds for all classes:
fwSetToCustom - Sets the boundary and alarm level to custom.
fwSetToDefault - Restores the boundary and alarm level to the default.
E-mail notification configuration
In environments where it is critical that you are notified about errors quickly, you can use e-mail
notifications. With e-mail notifications, you can be notified of serious errors by e-mail or a pager, so
you can react quickly.
To configure e-mail notifications in a Telnet session, perform the following steps.
1. Enter the fwMailCfg command at the prompt.
The fwMailcfg menu displays.
1 : Show Mail Configuration Information
2 : Disable Email Alert
3 : Enable Email Alert
4 : Send Test Mail
5 : Set Recipient Mail Address for Email Alert
6 : Relay Host IP Configuration
7 : Quit
Select an item => : (1..7) [7]
2. Enter the number corresponding to the task you wish to perform.
Showing e-mail configuration information
1. Enter 1 in the fwMailCfg menu to view the current e-mail configuration classes.
The Config Show menu displays.
Config Show Menu
____________________________
1 : Environment class
2 : SFP class
3 : Port class
4 : Fabric class
5 : E-Port class
6 : F/FL Port (Optical) class
7 : Alpa Performance Monitor class
8 : End-to-End Performance Monitor class
9 : Filter Performance Monitor class
10 : Security class
11 : Resource class
12 : FRU class
13 : Quit
Select an item => : (1..13) [13]