Administrator Guide

44 Fabric Watch Administrator’s Guide
53-1002752-01
SFP monitoring guidelines and default settings
6
SFP monitoring default settings
The SFP default settings are shown in Table 8. The default alarm configuration (log all alarms only
to the error log) is sufficient. It is recommended that you do not allow alerts to go out as SNMP
traps. If other Port class issues are reported, review the error log for any supporting data for SFP
issues.
TABLE 8 SFP class default settings
Area Description Default threshold settings Default alarm
settings
Threshold state
Current Monitors SFP current Unit: mA
Time Base: none
Low: 0
High: 50
Buffer: 1
Below: 1
Above: 1
Out_of_range
Out_of_range
Receive power
(RXP)
Monitors receive
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Below: 1
Above: 1
Out_of_range
Out_of_range
Voltage Monitors SFP
electrical force in
volts
Unit: mV
Time Base: none
Low: 2970
High: 3630
Buffer: 10
Below: 1
Above: 1
Out_of_range
Out_of_range
Temperature Monitors SFP
temperature
Unit: Degrees C
Time Base: none
Low: -10
High: 85
Buffer: 3
Below: 1
Above: 1
Out_of_range
Out_of_range
Transmit power
(TXP)
Monitors transmit
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Below: 1
Above: 1
Out_of_range
Out_of_range
Power on hours Monitors the number
of hours the 16 Gbps
SFP is powered.
Unit: Changes
Time Base: none
Low: 0
High: 0
Buffer: 0
Below: 0
Above: 0
Informative
Informative