62 Fabric Watch Administrator’s Guide
53-1002752-01
portThConfig command procedures
7
Area: Class 3 (C3) Discards
Unlike the other areas, take a conservative approach for the C3 Discards area. Use the default
settings and configure the alarms for Above. The goal is to determine the high boundary at
which the port would be fenced, so monitor the high boundary and change the settings
accordingly.
Area: Trunk Utilization
Set the high boundary to 75 percent and the alarms to Above and In-Between conditions.
These settings indicate if the 75 percent threshold is exceeded and for how long.
Areas: Primitive Sequence Protocol Error, State Changes, Utilization, Packet Loss
Use the default settings.
E_Port class default settings
Table 17 provides default settings for areas in the E_Port class.
Port fencing can be enabled or disabled for the following areas for the E_Port class:
Link Failure Count
Loss of Synchronization Count
Primitive Sequence Protocol Error
Invalid Transmission Word
Invalid CRC Count
TABLE 17 E_Port class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Cyclic redundancy
check (CRC)
Monitors the
number of CRC
errors.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Invalid transmission
words (ITW)
Monitors the
number of invalid
words transmitted.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Class 3 discards
(C3TX_TO)
Class 3 discards
frames due to time
out or destination
unreachable.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Link loss Monitors the
number of link
failures.
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative