Command Reference Guide

Fabric OS Command Reference 257
53-1002746-01
errDump
2
To display messages based on count value:
switch:admin> errdump --count 3
Fabric OS: v7.1.0errDump
2012/06/18-20:23:09, [LOG-1003], 1, SLOT 5 | CHASSIS, INFO, \
pluto_19, The log has been cleared.
2012/06/18-20:24:52, [SULB-1001], 2, SLOT 5 | CHASSIS, WARNING, \
pluto_19, Firmwaredownload command has started.
2012/06/18-20:24:52, [SULB-1036], 3, SLOT 5 | CHASSIS, INFO, \
pluto_19, The current Version: Fabric OS v7.1.0_rasadmin
To display raslog messages based on a message ID:
switch:admin> errdump --message EM-5012
Msg Id recieved = EM-5012
Fabric OS: v7.1.0errdump_opt_add
2012/10/17-05:45:28:562789, [EM-5012], 0, CHASSIS, INFO, chassis_1, \
start emd FSS_RECOV_WARM, emfss.c, line: 216, comp:emd, \
ltime:2012/10/17-05:45:28:562618
2012/10/17-05:45:31:120123, [EM-5012], 0, CHASSIS, INFO, chassis_1, \
end emd FSS_RECOV_ACTIVE (warm), emfss.c, line: 486, comp:emd, \
ltime:2012/10/17-05:45:31:120114
2012/10/17-05:45:33:423814, [EM-5012], 0, CHASSIS, INFO, chassis_1, \
EM: sent chassis ready event., em.c, line: 2200, comp:emd, \
ltime:2012/10/17-05:45:33:423804
2012/10/17-05:45:33:424052, [EM-5012], 0, CHASSIS, INFO, chassis_1, \
EM: called fss_notify_status., em.c, line: 2225, comp:emd, \
ltime:2012/10/17-05:45:33:424043
SEE ALSO errDelimiterSet, errFilterSet, errShow