Command Reference Guide

794 Fabric OS Command Reference
53-1002746-01
portShow
2
Edge fabric's primary WWN
If the EX_Port is connected to an edge switch with FCS policy enforcement, the
WWN of the primary FCS is displayed when the edge fabric is secure and the
primary FCS is online. Otherwise, displays "No Primary".
Edge fabric's version stamp
If the EX_PORT is connected to an edge switch with FCS policy enforcement, the
version of the security database is displayed. Otherwise displays N/A.
The portShow command displays FCoE ports with "Protocol: FCoE" and "portSpeed: 10Gbps". Only a
subset of information is displayed. Refer to the Examples section for an illustration. Use fcoe --cfgshow
and fcoe --loginshow to display FCoE-specific configuration details.
Following the general information, the command displays three columns of counters. The first column
shows interrupt statistics:
Interrupts
Total number of interrupts.
Unknown
Interrupts that are not counted elsewhere.
Lli
Low-level interface (physical state, primitive sequences).
Proc_rqrd
Frames delivered for embedded N_Port processing.
Timed_out
Frames that have timed out.
Rx_flushed
Frames requiring translation.
Tx_unavail
Frames returned from an unavailable transmitter.
Free_buffer
Free buffer available interrupts.
Overrun
Buffer overrun interrupts.
Suspended
Transmission suspended interrupts.
Parity_err
Central memory parity errors.
2_parity_err
Secondary transmission parity errors.
CMI_bus_err
Control message interface errors.
The second column displays link error status block counters.
The third column shows the number of F_RJTs and F_BSYs generated. For L_Ports, the third column
also displays the number of loop initialization protocols (LIPs) received, number of LIPs transmitted, and
the last LIP received.
OPERANDS This command has the following port operands:
slot
For bladed systems only, specifies the slot number of the port to be displayed,
followed by a slash (/).