Troubleshooting and Diagnostics Guide

96 Fabric OS Troubleshooting and Diagnostics Guide
53-1002751-01
Diagnostic Port (D_Port)
10
1. Disable Port 1 on Switch A, by using the portDisable [slot/]port command.
switchA:admin> portdisable 1
2. Configure Port 1 on Switch A as a D_Port, by using portCfgDport - -enable [slot/]port.
switchA:admin> portcfgdport --enable 1
3. Repeat steps 1 and 2 for the corresponding port (in this example Port 2) on Switch B.
switchB:admin> portdisable 2
switchB:admin> portcfgdport --enable 2
4. Enable Port 1 on Switch A by using the portEnable [slot/]port command.
switchA:admin> portenable 1
5. Enable Port 2 on Switch B using the portEnable [slot/]port command.
switchB:admin> portenable 2
The basic test suite starts as soon as both ports are enabled. The order in which they are enabled
does not matter.
6. While the test is running, enter the portDportTest [slot/]port - -show command to view test
results. The following test is successful.
switch:admin> portdporttest --show 10/39
D-Port Information:
===================
Slot: 10
Port: 39
Remote WWNN: 10:00:00:05:33:7e:69:c4
Remote port: 24
Mode: Manual
No. of test frames: 12 Million
Test frame size: 1024 Bytes
Payload Pattern: JTSPAT
FEC (enabled/option/active): Yes/No/No
CR (enabled/option/active): No/No/No
Start time: Mon Jan 16 05:57:51 2012
End time: Mon Jan 16 05:58:56 2012
Status: PASSED
=============================================================================
Test Start time Result EST(HH:MM:SS) Comments
=============================================================================
===
Electrical loopback 05:57:52 PASSED --------- ----------
Optical loopback 05:58:06 PASSED -------- ----------
Link traffic test 05:58:13 PASSED -------- ----------
=============================================================================
Roundtrip link latency: 934 nano-seconds
Estimated cable distance: 1 meters
Buffers required: 1 (for 1024 byte frames at 16Gbps speed)