Troubleshooting and Diagnostics Guide

Fabric OS Troubleshooting and Diagnostics Guide 33
53-1002751-01
Device login issues
3
Device login issues
A correct login is when the port type matches the device type that is plugged in. In the following
example, it shows that the device connected to Port 1 is a fabric point-to-point device and it is
correctly logged in an F_Port.
switch:admin> switchshow
switchName:brcd5300
switchType:64.3
switchState:Online
switchMode:Native
switchRole:Subordinate
switchDomain:1
switchId:fffc01
switchWwn:10:00:00:05:1e:40:ff:c4
zoning:OFF
switchBeacon:OFF
FC Router:OFF
FC Router BB Fabric ID:1
Area Port Media Speed State Proto
=====================================
0 0 -- N8 No_Module
1 1 -- N4 Online FC F-Port 10:00:00:05:1e:8f:c1:31
2 2 -- N8 No_Module
3 3 -- N8 No_Module
(output truncated)
61 61 -- N8 No_Module
62 62 -- N8 No_Module
63 63 -- N8 No_Module
64 64 id N2 Online E-Port 10:00:00:05:1e:34:d0:05 "1_d1"
(Trunk master)
65 65 -- N8 No_Module
66 66 -- N8 No_Module
67 67 id AN No_Sync
68 68 id N2 Online L-Port 13 public
69 69 -- N8 No_Module
70 70 -- N8 No_Module
71 71 id N2 Online L-Port 13 public
72 72 -- N8 No_Module
73 73 -- N8 No_Module
74 74 -- N8 No_Module
75 75 -- N8 No_Module
76 76 id N2 Online E-Port 10:00:00:05:1e:34:d0:05 "1_d1"
(upstream)(Trunk master)
77 77 id N4 Online F-Port 10:00:00:06:2b:0f:6c:1f
78 78 -- N8 No_Module
79 79 id N2 Online E-Port 10:00:00:05:1e:34:d0:05 "1_d1"
(Trunk master)
Pinpointing problems with device logins
1. Log in to the switch as admin.
2. Enter the switchShow command; then, check for state logins.
3. Enter the portCfgShow command to see if the port is configured correctly.