Quick Reference Guide

PowerConnect B-Series TI24X Configuration Guide 1065
53-1002269-02
Syslog messages
34
Notification VRRP intf state changed,
intf <portnum>, vrid <virtual-router-id>,
state <vrrp-state>
A state change has occurred in a Virtual
Router Redundancy Protocol (VRRP)
interface.
The <portnum> is the port.
The <virtual-router-id> is the virtual router
ID (VRID) configured on the interface.
The <vrrp-state> can be one of the
following:
init
master
backup
unknown
Warning DOT1X security violation at port <portnum>,
malicious mac address detected:
<mac-address>
A security violation was encountered at the
specified port number.
Warning Dup IP <ip-addr> detected, sent from MAC
<mac-addr> interface <portnum>
Indicates that the device received a packet
from another device on the network with an
IP address that is also configured on the
device.
The <ip-addr> is the duplicate IP address.
The <mac-addr> is the MAC address of the
device with the duplicate IP address.
The <portnum> is the port that received the
packet with the duplicate IP address. The
address is the packet source IP address.
Warning IGMP/MLD no hardware vidx, broadcast to
the entire vlan. rated limited number
IGMP or MLD snooping has run out of
hardware application VLANs. There are
4096 application VLANs per device. Traffic
streams for snooping entries without an
application VLAN are switched to the entire
VLAN and to the CPU to be dropped. This
message is rate-limited to appear a
maximum of once every 10 minutes. The
rate-limited number shows the number on
non-printed warnings.
Warning IGMP/MLD: <vlanId>(<portId>) is V1 but
rcvd V2 from nbr <ipAddr>
Port has received a query with a MLD
version that does not match the port MLD
version. This message is rated-limited to
appear a maximum of once every 10 hours.
Warning Latched low RX Power | TX Power | TX Bias
Current | Supply Voltage | Temperature
warning
alarm | warning, port <port-number>
The optical transceiver on the given port
has risen above or fallen below the alarm or
warning threshold.
TABLE 168 Dell Syslog messages (Continued)
Message level Message Explanation