Quick Reference Guide
PowerConnect B-Series TI24X Configuration Guide 1075
53-1002269-02
Basic management
A
Syntax: show transmit-counter values <number>
where <number> identifies a valid enhanced traffic counter and is a value from 1 – 64.
TABLE 170 Outbound traffic counter statistics
This line... Displays...
Transmitted frames
Known Unicast The number of known unicast packets transmitted.
Multicast & Unknown Unicast The number of multicast and unknown unicast packets transmitted.
Broadcast The number of broadcast packets transmitted.
Dropped Frames
Bridge Egress Filtered The number of bridged outbound packets that were filtered and dropped.
This number includes the number of packets that were dropped because of
any one of the following conditions:
• The port was disabled or the link was down.
• The port or port region does not belong to the VLAN specified in the
transmit counter configuration.
• A Layer 2 protocol (e.g., spanning tree) had the port in a Blocked state.
• The source port was suppressed for multi-target packets.
• The priority queue specified in the traffic counter was not allowed for
some other reason.
• Unknown unicast and unregistered multicast packets were filtered.
Congestion Drops The number of outbound packets that were dropped because of traffic
congestion.
PowerConnect#show transmit-counter values 1
Transmit Queue Counter Values for Counter 1:
Transmitted Frames:
Known Unicast : 17204
Multicast & Unknown Unicast : 2797
Broadcast : 5
Dropped Frames:
Bridge Egress Filtered : 2
Congestion Drops : 0
PowerConnect#show transmit-counter values 4
Transmit Queue Counter Values for Counter 4:
Transmitted Frames:
Known Unicast : 124
Multicast & Unknown Unicast : 2752
Broadcast : 0
Dropped Frames:
Bridge Egress Filtered : 37
Congestion Drops : 0