Quick Reference Guide

396 PowerConnect B-Series TI24X Configuration Guide
53-1002269-02
Configuring port mirroring and monitoring
14
If you configure both ACL mirroring and ACL based rate limiting on the same port, then all
packets that match are mirrored, including the packets that exceed the rate limit.
Table 57 lists the number of mirror and monitor ports supported on the devices.
.
You can configure a mirror port specifically as an ingress port, an egress port, or both.
Mirror ports can run at any speed and are not related to the speed of the ingress or egress
monitored ports.
The same port cannot be both a monitored port and the mirror port.
The same port can be monitored by one mirror port for ingress traffic and another mirror port
for egress traffic.
The mirror port cannot be a trunk port.
The monitored port and its mirror port do not need to belong to the same port-based VLAN:
If the mirror port is in a different VLAN from the monitored port, the packets are tagged
with the monitor port VLAN ID.
If the mirror port is in the same VLAN as the monitored port, the packets are tagged or
untagged, depending on the mirror port configuration.
More than one monitored port can be assigned to the same mirror port.
If the primary interface of a trunk is enabled for monitoring, the entire trunk will be monitored.
You can also enable an individual trunk port for monitoring using the config-trunk-ind
command.
For ingress ACL mirroring, the previous ingress rule also applies. The analyzer port setting
command acl-mirror-port must be specified for each port, even though the hardware only
supports one port per device. This applies whether the analyzer port is on the local device or
on a remote device. For example, when port mirroring is set to a remote device, any mirroring
(ACL, MAC filter, or VLAN) enabled ports are globally set to a single analyzer port, as shown in
the following example.
PowerConnect(config)# mirror ethernet 24
PowerConnect(config)# mirror ethernet 48
PowerConnect(config)# interface ethernet 1
PowerConnect(interface ethernet 1)# monitor ethernet 48 both
The analyzer port (48) is set to all devices in the system
PowerConnect# interface ethernet 2
PowerConnect(interface ethernet 2)# ip access-group 101 in
PowerConnect# exit
PowerConnect# interface ethernet 1
PowerConnect(interface ethernet 1)# acl-mirror-port ethernet 48
TABLE 57 Number of mirror and monitored ports supported
Port type Maximum ports
supported
PowerConnect
B-Series TI24X
Ingress mirror ports 1
Egress mirror ports 1
Ingress monitored ports no limit
Egress monitored ports no limit