Quick Reference Guide

24 PowerConnect B-Series TI24X Configuration Guide
53-1002269-02
Configuring basic port parameters
2
Use the show rate-limit unknown-unicast command to display the unknown unicast limit for each
port region to which it applies.
Syntax: show rate-limit unknown-unicast
Use the show rate-limit broadcast command to display the broadcast limit or broadcast and
multicast limit for each port to which it applies.
Syntax: show rate-limit broadcast
Configuring basic port parameters
The procedures in this section describe how to configure the port parameters shown in Table 6.
All ports are pre-configured with default values that allow the device to be fully operational at initial
startup without any additional configuration. However, in some cases, changes to the port
parameters may be necessary to adjust to attached devices or other network requirements.
TABLE 6 Basic port parameters
Port parameter See page
Name page 25
Speed page 25
Duplex mode page 26
Port status (enable or disable) page 27
Flow control page 27
Auto-negotiation and advertisement of flow control page 28
Configuring PHY FIFO Rx and TX Depth page 29
Interpacket Gap (IPG) page 29
Gbps fiber negotiate mode page 30
QoS priority page 30
Port flap dampening page 30