Quick Reference Guide

964 PowerConnect B-Series TI24X Configuration Guide
53-1002269-02
Sample 802.1X configurations
28
PowerConnect(config)# interface e 1
PowerConnect(config-if-e10000-1)# dot1x port-control auto
PowerConnect(config-if-e10000-1)# exit
PowerConnect(config)# interface e 2
PowerConnectconfig-if-e10000-2)# dot1x port-control auto
PowerConnect(config-if-e10000-2)# exit
PowerConnect(config)# interface e 3
PowerConnect(config-if-e10000-3)# dot1x port-control auto
PowerConnect(config-if-e10000-3)# exit
Hub configuration
Figure 124 illustrates a configuration where three 802.1X-enabled Clients are connected to a hub,
which is connected to a port on the Dell device. The configuration is similar to that in Figure 123,
except that 802.1X port security is enabled on only one port, and the multiple-hosts command is
used to allow multiple Clients on the port.
FIGURE 124 Sample 802.1X configuration using a hub
The following commands configure the Dell device in Figure 124
PowerConnect(config)# aaa authentication dot1x default radius
PowerConnect(config)# radius-server host 192.168.9.22 auth-port 1812 acct-port
1813 default key mirabeau dot1x
PowerConnect(config)# dot1x-enable e 1
PowerConnect(config-dot1x)# re-authentication
PowerConnect(config-dot1x)# timeout re-authperiod 2000
PowerConnect(config-dot1x)# timeout quiet-period 30
PowerConnect(config-dot1x)# timeout tx-period 60
PowerConnect(config-dot1x)# max-req 6
PowerConnect(config-dot1x)# exit
RADIUS Server
(Authentication Server)
Switch
(Authenticator)
Clients/Supplicants running 802.1X-compliant client software
e 1
192.168.9.22
Hub