Information Update 9
E07FA PROC n THERMTRIP Specified microprocessor is out of
acceptable temperature range and
has halted operation.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide. If the problem persists,
ensure that the microprocessor
heat sinks are properly installed.
See "Removing a Processor" in
your Installation
and Troubleshooting Guide.
NOTE: The LCD continues to
display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the Dell OpenManage
Baseboard Management
Controller User’s Guide for
information about these utilities.
E0876 PS n MISSING
PS n STATUS
No power available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Power
Supplies" in your Installation
and Troubleshooting Guide.
E0876 PS n PREDICTIVE Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.
See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide.
E0876 PS n AC LOST
PS n AC RANGE
Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source
for the specified power supply.
E0876 PS # AC OUT OF
RANGE - APPLY
200-240V
The AC power to the specified
power supply is out of operating
range.
Check the power source and
verify that it is supplying 215-
220V power. If the problem
persists, see "Getting Help"
in your Installation
and Troubleshooting Guide.
Table 1-2. LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes Corrective Actions