Users Guide

Feature Name PERC 9 Controllers PERC 8 Controllers PCIe
SSD
H830 H730
P
H730 H330 FD33x
S
FD33x
D
H810 H710P H710 H310
Reset controller
configuration
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Staged Staged Staged Staged Not
applicabl
e
Create or change
security keys
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Staged Staged Staged Staged Not
applicabl
e
Inventory and
remotely monitor the
health of PCIe SSD
devices
Not
applic
able
Not
applic
able
Not
applica
ble
Not
applica
ble
Not
applica
ble
Not
applica
ble
Not
applicabl
e
Not
applicable
Not
applicabl
e
Not
applicab
le
Real-
time
Prepare the PCIe
SSD to be removed
Not
applic
able
Not
applic
able
Not
applica
ble
Not
applica
ble
Not
applica
ble
Not
applica
ble
Not
applicabl
e
Not
applicable
Not
applicabl
e
Not
applicab
le
Real-
time
Securely erase the
data
Not
applic
able
Not
applic
able
Not
applica
ble
Not
applica
ble
Not
applica
ble
Not
applica
ble
Not
applicabl
e
Not
applicable
Not
applicabl
e
Not
applicab
le
Staged
Configure Backplane
mode
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Not
applicabl
e
Not
applicable
Not
applicabl
e
Not
applicab
le
Not
applicabl
e
Blink or unblink
component LEDs
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Real-
time
Real-time Real-
time
Real-
time
Real-
time
Switch controller
mode
Stage
d
Stage
d
Staged Staged Staged Staged Not
applicabl
e
Not
applicable
Not
applicabl
e
Not
applicab
le
Not
applicabl
e
Inventorying and monitoring storage devices
You can remotely monitor the health and view the inventory of the following Comprehensive Embedded Management (CEM)
enabled storage devices in the managed system using iDRAC web interface:
RAID controllers, non-RAID controllers, and PCIe extenders
Enclosures that include Enclosure Management Modules (EMMs), power supply, fan probe, and temperature probe
Physical disks
Virtual disks
Batteries
However, RACADM and WS-MAN display information for most of the storage devices in the system.
The recent storage events and topology of storage devices are also displayed.
Alerts and SNMP traps are generated for storage events. The events are logged in the Lifecycle Log.
NOTE: If you enumerate the enclosure view's WSMAN command on a system while one PSU-cable is removed, the
primary status of the enclosure view is reported as Healthy instead of Warning.
Monitoring storage devices using web interface
To view the storage device information using Web interface:
184