Users Guide

Managing virtual disks using web interface
1. In the iDRAC web interface, go to OverviewStorageVirtual DisksManage.
The Manage Virtual Disks page is displayed.
2. From the Controller drop-down menu, select the controller for which you want to manage the virtual disks.
3. For one or more Virtual Disks, from each Action drop-down menu, select an action.
You can specify more than one action for a virtual drive. When you select an action, an additional Action drop-down menu is
displayed. Select another action from this drop-down menu. The action that is already selected does not appear in the
additional Action drop-down menus. Also, the Remove link is displayed next to the selected action. Click this link to remove the
selected action.
Delete
Edit Policy: Read Cache — Change the read cache policy to one of the following options:
No Read Ahead
Read Ahead
Adaptive Read Ahead
NOTE: Previous generations of PERC controllers support read policy settings of No Read Ahead, Read
Ahead, and Adaptive Read Ahead. With PERC 8 and PERC 9, the Read Ahead and Adaptive Read Ahead
settings are functionally equivalent at the controller level. For backward compatibility purposes, some
systems management interfaces and PERC 8 and 9 controllers still allow setting the read policy to Adaptive
Read Ahead. While it is possible to set Read Ahead or Adaptive Read Ahead on PERC 8 or PERC 9, there is
no functional difference.
Edit Policy: Write Cache — Change the write cache policy to one of the following options:
Write Through
Write Back
Force Write Back
Edit Policy: Disk Cache — Change the disk cache policy to one of the following options:
Default
Enabled
Disabled
Initialize: Fast — Updates the metadata on the physical disks so that all the disk space is available for future write
operations. The initialize option can be completed quickly because existing information on the physical disks is not erased,
although future write operations overwrites any information that remains on the physical disks.
Initialize: Full — All existing data and file systems are erased.
NOTE: The Initialize: Full option is not applicable for PERC H330 controllers.
Check Consistency — To check the consistency of a virtual disk, select Check Consistency from the corresponding drop-
down menu.
NOTE: Consistency check is not supported on drives set up in RAID0 mode.
Encrypt Virtual Disk — Encrypts the virtual disk drive. If the controller is encryption capable, you can create, change or
delete the security keys.
NOTE: The Encrypt Virtual Disk option is available only if the virtual disk is created using the Self-Encrypting
Drive (SED) drives.
Manage Dedicated Hotspares — Assign or unassign a physical disk as a dedicated hot spare. Only the valid dedicated hot
spares are displayed. If there are no valid dedicated hot spares, then this section does not appear in the drop-down menu.
For more information about these options, see the iDRAC Online Help.
4. From the Apply Operation Mode drop-down menu, select when you want to apply the settings.
5. Click Apply.
Based on the selected operation mode, the settings are applied.
192