The check consistency rate, configurable between 0% and 100%, represents the percentage of the system resources dedicated to
running the check consistency task. At 0%, the check consistency has the lowest priority for the controller, takes the most time to
complete, and is the setting with the least impact to system performance. A check consistency rate of 0% does not mean that the
check consistency is stopped or paused. At 100%, the check consistency is the highest priority for the controller. The check
consistency time is minimized and is the setting with the most impact to system performance.
Create or change security keys
When configuring the controller properties, you can create or change the security keys. The controller uses the encryption key to
lock or unlock access to SED. You can create only one encryption key for each encryption-capable controller. The security key is
managed using the Local Key Management (LKM) feature. LKM is used to generate the key ID and the password or key required to
secure the virtual disk. If you are using LKM, you must create the encryption key by providing the Security Key Identifier and the
Passphrase.
This task is not supported on PERC hardware controllers running in HBA mode.
If you create the security key-in Add to Pending Operation mode and a job is not created, and then if you delete the security key,
the create security key pending operation is cleared.
Configuring controller properties using web interface
1. In the iDRAC web interface, go to OverviewStorageControllersSetup.
The Setup Controllers page is displayed.
2. In the Configure Controller Properties section, from the Controller drop-down menu, select the controller that you want to
configure.
3. Specify the required information for the various properties.
The Current Value column displays the existing values for each property. You can modify this value by selecting the option
from the Action drop-down menu for each property.
For information about the fields, see the iDRAC Online Help.
4. From the Apply Operation Mode drop-down menu, select when you want to apply the settings.
5. Click Apply.
Based on the selected operation mode, the settings are applied.
Configuring controller properties using RACADM
To set Patrol Read Mode:
racadm set storage.controller.<index>.PatrolReadMode {Automatic | Manual | Disabled}
If Patrol read mode is set to manual, use the following commands to start and stop Patrol read Mode:
racadm storage patrolread:<Controller FQDD> -state {start|stop}
NOTE: Patrol read mode operations such as Start and Stop are not supported if there are no virtual disks available in
the controller. Though you can invoke the operations successfully using the iDRAC interfaces, the operations will fail
when the associated job is started.
To specify the Check Consistency Mode, use Storage.Controller.CheckConsistencyMode object.
To enable or disable the Copyback Mode, use Storage.Controller.CopybackMode object.
To enable or disable the Load Balance Mode, use Storage.Controller.PossibleloadBalancedMode object.
To specify the percentage of the system's resources dedicated to perform a check consistency on a redundant virtual disk, use
Storage.Controller.CheckConsistencyRate object.
To specify the percentage of the controller's resources dedicated to rebuild a failed disk, use Storage.Controller.RebuildRate
object
To specify the percentage of the controller's resources dedicated to perform the background initialization (BGI) of a virtual disk
after it is created, useStorage.Controller.BackgroundInitializationRate object
To specify the percentage of the controller's resources dedicated to reconstruct a disk group after adding a physical disk or
changing the RAID level of a virtual disk residing on the disk group, use Storage.Controller.ReconstructRate object
To enable or disable the enhanced auto import of foreign configuration for the controller, use
Storage.Controller.EnhancedAutoImportForeignConfig object