Object Description Usage Example
fan speed increasing to full
speed.
racadm set
system.thermalsetting
s FanSpeedOffset 3
FanSpeedMediumOffsetV
al
Getting this variable reads
the fan speed offset value
in %PWM for Medium Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset
object to set this value
using index value 2
Values from 0-100
racadm get
system.thermalsetting
s
FanSpeedMediumOffsetV
al
This returns a value such as
“47”. This means that when
you use the following
command, it applies a fan
speed offset of Medium (47%
PWM) over baseline fan speed
racadm set
system.thermalsetting
s FanSpeedOffset 2
FanSpeedOffset
Using this object with get
command displays the
existing Fan Speed Offset
value.
Using this object with set
command allows setting
the required fan speed
offset value.
The index value decides
the offset that is applied
and the
FanSpeedLowOffsetVa
l,
FanSpeedMaxOffsetVa
l,
FanSpeedHighOffsetV
al
, and
FanSpeedMediumOffse
tVal objects (defined
earlier) are the values at
which the offsets are
applied.
Values are:
0 — Low Fan Speed
1 — High Fan Speed
2 — Medium Fan Speed
3 — Max Fan Speed
255 — None
To view the existing setting:
racadm get
system.thermalsetting
s.FanSpeedOffset
To set the fan speed offset to
High value (as defined in
FanSpeedHighOffsetVal)
racadm set
system.thermalsetting
s.FanSpeedOffset 1
MFSMaximumLimit
Read Maximum limit for MFS
Values from 1 — 100 To display the highest value
that can be set using
MinimumFanSpeed option:
racadm get
system.thermalsetting
s.MFSMaximumLimit
MFSMinimumLimit
Read Minimum limit for MFS
Values from 0 to
MFSMaximumLimit
Default is 255 (means None)
To display the lowest value
that can be set using
MinimumFanSpeed option.
racadm get
system.thermalsetting
s.MFSMinimumLimit
MinimumFanSpeed
Allows configuring the
Minimum Fan speed that is
required for the system to
operate.
Values from
MFSMinimumLimit to
MFSMaximumLimit
To make sure that the system
minimum speed does not
decrease lower than 45%
PWM (45 must be a value
53