Owners Manual

Figure 62. Removing the system battery
3. To install a new system battery, hold the battery with the positive side facing up and slide it under the securing tabs.
4. Press the battery into the connector until it snaps into place.
Figure 63. Installing the system battery
Next steps
1. Install the expansion card riser 1.
2. Follow the procedure listed in After working inside your system on page 24.
3. While booting, press F2 to enter the System Setup and ensure that the battery is operating properly.
4. Enter the correct time and date in the System Setup Time and Date fields.
5. Exit the System Setup.
Optional internal USB memory key
NOTE: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
Replacing the optional internal USB memory key
Prerequisites
CAUTION:
To avoid interference with other components in the server, the maximum permissible dimensions of
the USB memory key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1. Follow the safety guidelines listed in Safety instructions on page 23.
2. Follow the procedure listed in Before working inside your system on page 24.
Steps
1. Locate the USB port or USB memory key on the system board.
To locate the USB port, see the Jumpers and connectors section.
2. If installed, remove the USB memory key from the USB port.
3. Insert the replacement USB memory key into the USB port.
PowerEdge C4140 installing and removing system components
63