Users Guide

Table Of Contents
Setting alert recurrence events using iDRAC web interface
To set the alert recurrence value:
1. In iDRAC Web interface, go to Configuration > System Settings > Alert Recurrence.
2. In the Recurrence column, enter the alert frequency value for the required category, alert, and severity type(s).
For more information, see the iDRAC Online help.
3. Click Apply.
The alert recurrence settings are saved.
Setting event actions
You can set event actions such as perform a reboot, power cycle, power off, or perform no action on the system.
Setting event actions using web interface
To set an event action:
1. In iDRAC Web interface, go to Configuration > System Settings > Alert and Remote System Log Configuration.
2. From the Actions drop-down menu, for each event select an action:
Reboot
Power Cycle
Power Off
No Action
3. Click Apply.
The setting is saved.
Setting event actions using RACADM
To configure an event action, use the eventfilters command. For more information, see the iDRAC RACADM CLI Guide
available at https://www.dell.com/idracmanuals.
Configuring email alert, SNMP trap, or IPMI trap
settings
The management station uses Simple Network Management Protocol (SNMP) and Intelligent Platform Management Interface
(IPMI) traps to receive data from iDRAC. For systems with large number of nodes, it may not be efficient for a management
station to poll each iDRAC for every condition that may occur. For example, event traps can help a management station with
load balancing between nodes or by issuing an alert if an authentication failure occurs. SNMP v1, v2, and v3 formats are
supported.
You can configure the IPv4 and IPv6 alert destinations, email settings, and SMTP server settings, and test these settings. You
can also specify the SNMP v3 user to whom you want to send the SNMP traps.
Before configuring the email, SNMP, or IPMI trap settings, make sure that:
You have Configure RAC permission.
You have configured the event filters.
Configuring IP alert destinations
You can configure the IPv6 or IPv4 addresses to receive the IPMI alerts or SNMP traps.
For information about the iDRAC MIBs required to monitor the servers using SNMP, see the Dell EMC OpenManage SNMP
Reference Guide available at https://www.dell.com/openmanagemanuals.
174
Configuring iDRAC to send alerts