Users Guide

Table Of Contents
To create the target job after executing the secureerase command:
racadm jobqueue create <PCIe SSD FQDD> -s TIME_NOW -e <start_time>
To query the job ID returned:
racadm jobqueue view -i <job ID>
For more information, see the iDRAC RACADM Command Line Reference Guide available at dell.com/idracmanuals.
Managing enclosures or backplanes
You can perform the following for enclosures or backplanes:
View properties
Configure universal mode or split mode
View slot information (universal or shared)
Set SGPIO mode
Set Asset Tag
Asset Name
Configuring backplane mode
The Dell 14
th
generation PowerEdge servers supports a new internal storage topology, where two storage controllers (PERCs)
can be connected to a set of internal drives through a single expander. This configuration is used for high performance mode
with no failover or High Availability (HA) functionality. The expander splits the internal drive array between the two storage
controllers. In this mode, virtual disk creation only displays the drives connected to a particular controller. There are no licensing
requirements for this feature. This feature is supported only on a few systems.
Backplane supports the following modes:
Unified mode This is the default mode. The primary PERC controller has access to all the drives connected to the
backplane even if a second PERC controller is installed.
Split mode One controller has access to the first 12 drives and the second controller has access to the last 12 drives. The
drives connected to the first controller are numbered 0-11 while the drives connected to the second controller are numbered
12-23.
Split mode 4:20 One controller has access to the first 4 drives and the second controller has access to the last 20
drives. The drives connected to the first controller are numbered 0-3 while the drives connected to the second controller are
numbered 4-23.
Split mode 8:16 One controller has access to the first 8 drives and the second controller has access to the last 16
drives. The drives connected to the first controller are numbered 0-7 while the drives connected to the second controller are
numbered 8-23.
Split mode 16:8 One controller has access to the first 16 drives and the second controller has access to the last 8 drives.
The drives connected to the first controller are numbered 0-15 while the drives connected to the second controller are
numbered 16-23.
Split mode 20:4 One controller has access to the first 20 drives and the second controller has access to the last 4 drives.
The drives connected to the first controller are numbered 0-19 while the drives connected to the second controller are
numbered 20-23.
Split mode 6:6:6:6 4 blades installed in one chassis and each blade have 6 drives assigned. This mode is only supported on
PowerEdge C series blades.
Information Not Available Controller information is not available.
iDRAC allows the split mode setting if the expander has the capability to support the configuration. Ensure that you enable this
mode prior to installing the second controller. iDRAC performs a check for expander capability prior to allowing this mode to be
configured and does not check whether the second PERC controller is present.
NOTE:
Cable errors (or other errors) may appear if you put the backplane into split mode with only one PERC attached, or
if you put the backplane into Unified Mode with two PERCs attached.
To modify the setting, you must have Server Control privilege.
If any other RAID operations are in pending state or any RAID job is scheduled, you cannot change the backplane mode.
Similarly, if this setting is pending, you cannot schedule other RAID jobs.
260
Managing storage devices