Dell PowerEdge C6145 Getting Started With Your System 系统使用入门 Mengaktifkan Sistem Anda はじめに 시스템시작 안내서
Dell PowerEdge C6145 Getting Started With Your System
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Information in this publication is subject to change without notice. © 2011 Dell Inc. All rights reserved.
CAUTION: Restricted Access Location This server is intended for installation only in restricted access locations as defined in Cl. 1.2.7.3 of IEC 60950-1: 2001 where both these conditions apply: Access can only be gained by service persons or by users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken.
1 Pull on the latch release buttons on the end piece midpoints to open the rail latches. 2 Align the end pieces of the rails on the vertical rack flanges to seat the pegs in the bottom hole of the first U and the top hole of the second U. Engage the back end of the rails until the latches lock in place. NOTE: The rails can be used in both square-hole (item 1 in the following figure) and round-hole racks (item 2 in the following figure).
6 Slide the system into the rack. 7 Tighten the thumbscrews to secure the ears of the system to the front of the rack flanges.
Optional-Connecting the Keyboard, Mouse, and Monitor Connect the keyboard, mouse, and monitor (optional). The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor’s cable connector.
Connecting the Power Cable(s) Connect the system’s power cable(s) to the system and, if a monitor is used, connect the monitor’s power cable to the monitor. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply or a power distribution unit.
Turning on the System Press the power button(s) either on the front or back of the system and on the monitor. The power indicators should light.
Complete the Operating System Setup To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system.
Other Information You May Need WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. The Hardware Owner’s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. This document is available at support.dell.com/manuals.
Technical Specifications Processor (Per System Board) Processor type Four AMD Opteron 6100 Series processors Expansion Bus (Per System Board) Bus type PCI Express Generation 2 Expansion slots PCIe One x16, low profile Two x16, half-length/half-height Daughter card PCIe One x16, Mezzanine slot Memory (Per System Board) Architecture 32 x DDR3 1066/1333 MHz RDIMM or UDIMM Memory module sockets 32 x DDR3 DIMM sockets Memory module capacities 2 GB, 4 GB, 8 GB, or 16 GB Minimum RAM 64 GB Maximu
Video 15-pin D-Sub VGA Management port Dedicated Ethernet port for remote management access Video (Per System Board) Video type On-board AST2050 video controller Video memory 8 MB Power AC power supply (per power supply) Wattage 1023 W low line/1100 W high line Voltage 100-240 V CA, 50-60 Hz, maximum input current: 12.0 Amps Heat dissipation 4217.063 BTU/hr maximum Wattage 1400 W Voltage 200-240 V CA, 50-60 Hz, maximum input current: 8.
Environmental NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets. Temperature Operating 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1°F/550 ft.
Environmental Altitude Operating –16 to 3,048 m (–50 to 10,000 ft) NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1°F/550 ft. Storage –16 to 10,600 m (–50 to 35,000 ft) Airborne contaminant level Class Getting Started With Your System G2 or lower as defined by ISA-S71.
Dell PowerEdge C6145 系统使用入门
注、小心和警告 注:"注"表示可以帮助您更好地使用计算机的重要信息。 小心:"小心"表示如果不遵循说明,就有可能损坏硬件或导致数据丢失。 警告:"警告"表示可能会导致财产损失、人身伤害甚至死亡。 ______________ 本出版物中的信息如有更改,恕不另行通知。 © 2011 Dell Inc. 版权所有,翻印必究。 未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。 本文中使用的商标:Dell™、DELL 徽标和 PowerEdge™ 是 Dell Inc. 的商 标。AMD® 和 AMD Opteron™ 是 Advanced Micro Devices, Inc. 的注册商标 和商标。Red Hat Enterprise Linux® 和 Enterprise Linux® 是 Red Hat, Inc. 在美 国和/或其它国家/地区的注册商标。Novell® 和 SUSE™ 是 Novell Inc. 在美 国和其它国家/地区的注册商标和商标。Citrix® 和 XenServer® 是 Citrix Systems, Inc.
小心:受限访问位置 此服务器仅适用于安装在 IEC 60950-1:2001 的 Cl. 1.2.7.
1 拔起尾段正中央的闩锁释放按钮以打开导轨闩锁。 2 对齐垂直机架边缘上的导轨尾段,将连接销按入第一个 U 底部 的孔和第二个 U 顶部的孔中。接合导轨后端直到闩锁锁定到位。 注:导轨可同时用于方孔(下图中的项目 1)和圆孔机架 (下图中的项目 2)。 后视图 正面视图 3 重复步骤 1 和步骤 2 定位前端段并将其固定在垂直边缘。 注:要卸下导轨,请拔起尾段正中央的闩锁释放按钮并取出每个导轨。 4 在背面的每个垂直机架边缘,将两个螺钉座放入导轨正上方的 两个方孔。 5 在背面机架边缘安装运输时稳固机箱的支架(可选)并同时拧 紧螺钉。 注:要运输已经安装在机架上的系统,请确保两个运输时稳固机箱的支架 到位(可选)。 系统使用入门 | 20
后视图 6 将系统滑入到机架中。 7 拧紧指旋螺钉,将系统吊耳固定到机架边缘正面。 后视图 正面视图 系统使用入门 | 21
可选 – 连接键盘、鼠标和显示器 连接键盘、鼠标和显示器(可选)。 系统背面的连接器附有图标,这些图标指示了要插入每个连接器的电缆。 确保拧紧显示器电缆连接器上的螺钉(如果有)。 系统使用入门 | 22
连接电源电缆 将系统电源电缆连接至系统,如果使用显示器,则将显示器电源电缆连接 至显示器。将电源电缆的另一端插入接地的电源插座或单独的电源,如不 间断电源设备或配电装置。 系统使用入门 | 23
开启系统 按系统正面或背面或者显示器上的电源按钮。电源指示灯将会亮起。 系统使用入门 | 24
完成操作系统安装 第一次安装操作系统时,请参阅操作系统的安装和配置说明文件。请确保 先安装操作系统,然后再安装未随系统一起购买的硬件或软件。 支持的操作系统 Microsoft Windows HPC Server 2008 R2(64 位) Microsoft Windows Server 2008 Core R2(64 位) Microsoft Windows Server 2008 R2 Hyper-V Microsoft Windows Server 2008 R2 Enterprise(64 位) Red Hat Enterprise Linux 5.5(64 位) Red Hat Enterprise Linux 6.0(仅限认证) SUSE Linux Enterprise Server 11 SP1(64 位) VMware ESX Server 4.1 U1 和 ESXi(嵌入式) Citrix XenServer 5.6 Feature Pack 1 注:有关支持的操作系统的最新信息,请访问 support.dell.
可能需要的其它信息 警告:请参阅系统随附的安全与管制信息。保修信息可能包括在该说明文件中,也可 能作为单独的说明文件提供。 《硬件用户手册》提供了有关系统功能的信息,并说明了如何排除系统故 障以及安装或更换系统组件。该说明文件可从 support.dell.com/manuals 获得。 Dell 系统管理应用程序说明文件提供了有关如何安装和使用系统管理软件 的信息。该说明文件可从 support.dell.com/manuals 在线获得。 注:请经常访问 support.dell.
技术规格 处理器(每个系统板) 处理器类型 四个 AMD Opteron 6100 系列处理器 扩展总线(每个系统板) 总线类型 第二代 PCI Express 扩充槽 PCIe 一个 x16,小型 两个 x16,半长/半高 PCIe 子卡 一个 x16,夹层卡插槽 内存(每个系统板) 体系结构 32 x DDR3 1066/1333 MHz RDIMM 或 UDIMM 内存模块插槽 32 x DDR3 DIMM 插槽 内存模块容量 2 GB、4 GB、8 GB 或 16 GB 最小 RAM 64 GB 最大 RAM 512 GB 驱动器 硬盘驱动器 多达 12 个 3.5 英寸、热插拔 SAS/SATA 驱动器或多达 24 个 2.
连接器(每个系统板) 背面 NIC 两个 RJ-45(10/100/1000 Mbps 以 太网) 串行 9 针、DTE、16550 兼容 USB 两个 4 针、USB 2.0 兼容 视频 15 针 D-Sub VGA 管理端口 用于远程管理访问的专用以太网 端口 视频(每个系统板) 显卡类型 机载 AST2050 视频控制器 视频内存 8 MB 电源 交流电源设备(每个电源设备) 功率 1023 W 低压线路/1100 W 高压线路 电压 100-240 V CA,50-60 Hz,最大输入 电流:12.0 A 散热 最大为 4217.063 BTU/小时 功率 1400 W 电压 200-240 V CA,50-60 Hz,最大输入 电流:8.6 A 散热 最大为 5724 BTU/小时 最大涌入电流 初始涌入电流不能超过 55 A(峰 值)。次级涌入电流不能超过 35 A (峰值)。 电池(每个系统板) 系统电池 CR 2032 3.0 V 锂币电池 RAID 电池(可选) 3.
内存 高度 8.76 厘米(3.45 英寸) 宽度 44.8 厘米(17.6 英寸) 厚度 79.0 厘米(31.1 英寸) 重量(最大配置) 42 千克(92.61 磅) 重量(空置) 16.5 千克(36.38 磅) 环境参数 注:有关具体系统配置的环境测量值的其它信息,请参阅 www.dell.com/environmental_datasheets。 温度 运行时 10° 至 35°C(50° 至 95°F),最大温 度变化梯度为每小时 10°C 注:海拔高度在 2950 英尺以上时,每升高 550 英 尺,最高操作温度降低 1°F。 存储时 –40° 至 65°C(–40 ° 至 149°F),最 大温度变化梯度为每小时 20°C 相对湿度 运行时 20% 至 80%(非冷凝),最大湿度变 化梯度为每小时 10% 存储时 5% 至 95%(非冷凝) 最大振动 运行时 5–350 Hz 时 0.26 Grms 存储时 在 10-500 Hz、1.
最大撞击 z 轴正方向上可承受一个 运行时 31 G 的撞击脉冲(系统每一面各承 受一个脉冲),在运行方向上可持续 2.6 毫秒 x、y 和 z 轴正负方向上可承受连续六 个 71 G 的撞击脉冲(系统每一面承 受一个脉冲),最长可持续 2 毫秒; 存储时 x、y 和 z 轴正负方向上可承受连续六 个 22 G 正弦波脉冲的撞击脉冲(系 统每一面承受一个脉冲),速度变化 为 200 英寸/秒(508 厘米/秒) 海拔高度 –16 至 3,048 米(–50 至 10,000 英 尺) 运行时 注:海拔高度在 2950 英尺以上时, 每升高 550 英尺,最高操作温度降低 1°F。 -16 至 10,600 米(-50 至 35,000 英 尺) 存储时 气载污染物级别 G2 或更低(依据 ISA-S71.
Dell PowerEdge C6145 Mengaktifkan Sistem Anda
Catatan, Perhatian, dan Peringatan CATATAN: Sebuah CATATAN memberikan informasi penting yang dapat membantu Anda untuk menggunakan komputer Anda dengan lebih baik PERHATIAN: Sebuah PERHATIAN mengindikasikan potensi kerusakan terhadap perangkat keras atau kehilangan data jika petunjuk tidak diikuti. PERINGATAN: Sebuah PERINGATAN mengindikasikan potensi kerusakan properti, cidera diri, atau kematian. ______________ Informasi dalam dokumen ini dapat berubah tanpa pemberitahuan. © 2011 Dell Inc.
PERHATIAN: Lokasi Akses Terbatas Server ini dimaksudkan untuk instalasi di lokasi akses terbatas saja sebagaimana di definisikan di dalam Cl. 1.2.7.3 of IEC 60950-1: 2001 di mana kedua kondisi ini berlaku: Akses hanya dapat diperoleh oleh petugas servis atau pengguna yang telah diberitahu mengenai alasan-alasan pembatasan yang diterapkan pada lokasi tersebut dan tentang tindakan pencegahan yang harus dilakukan.
1 Tarik tombol-tombol pelepas pengunci yang ada di tengah bagian ujung untuk membuka pengunci-pengunci rel. 2 Sejajarkan bagian-bagian ujung dari rel pada flensa rak vertikal untuk mendudukkan pasak-pasak pada lubang bawah U pertama dan pada lubang atas U kedua. Sambungkan ujung belakang rel-rel sampai pengunci mengunci pada tempatnya. CATATAN: Rel-rel dapat digunakan baik pada rak lubang persegi (item 1 pada gambar berikut ini) maupun pada rak lubang bulat (item 2 pada gambar berikut ini).
Tampilan depan 6 Geser sistem ke dalam rak. 7 Kencangkan thumbscrew (sekrup yang bisa diputar dengan jari) untuk mengunci kuping-kuping sistem ke bagian depan flensa rak.
Opsional - Menghubungkan Keyboard, Mouse, dan Monitor Hubungkan keyboard, mouse, dan monitor (opsional). Konektor pada bagian belakang sistem Anda memiliki ikon yang menunjukkan kabel mana yang harus dimasukkan ke dalan setiap konektor. Pastikan untuk mengencangkan sekrup-sekrup (kalau ada) pada konektor kabel monitor.
Menghubungkan Kabel Daya Hubungkan kabel daya sistem ke sistem dan, jika monitor digunakan, hubungkan kabel daya monitor ke monitor. Masukkan ujung lainnya dari kabel daya ke lubang listrik yang telah dibumikan atau sumber tenaga listrik lainnya seperti UPS atau unit distribusi daya.
Menghidupkan Sistem Tekan tombol daya di bagian depan atau bagian belakang sistem dan pada monitor. Indikator daya harus menyala.
Menyelesaikan Pengaturan Sistem Operasi Untuk menginstal sistem operasi untuk pertama kali, lihat dokumentasi instalasi dan konfigurasi untuk sistem operasi Anda. Pastikan sistem operasi tersebut terinstal sebelum memasang perangkat keras atau perangkat lunak yang tidak dibeli bersama sistem.
Informasi Lain Yang Mungkin Diperlukan PERINGATAN: Lihat informasi keselamatan dan regulasi yang dikirimnkan bersama sistem Anda. Informasi jaminan mungkin disertakan di dalam dokumen ini atau di dalam dokumen terpisah. Buku Panduan Pemilik Perangkat Keras (Hardware Owner’s Manual) memberikan informasi mengenai fitur-fitur sistem dan menjelaskan mengenai cara mengatasi masalah serta cara memasang atau mengganti komponenkomponen sistem. Dokumen ini dapat diperoleh di support.dell.com/manuals.
Spesifikasi Teknis Prosesor (Per Papan Sistem) Jenis prosesor Empat prosesor Seri AMD Opteron 6100 Bus Expansi (Per Papan Sistem) Jenis bus PCI Express Generation 2 Slot ekspansi PCIe Satu x16, profil rendah Dua x16, separuh panjang/separuh tinggi Kartu anak PCIe Satu x16, Mezzanine slot Memori (Per Papan Sistem) Arsitektur 32 x DDR3 1066/1333 MHz RDIMM atau UDIMM Soket modul memori 32 x soket DDR3 DIMM Kapasitas modul memori 2 GB, 4 GB, 8 GB, atau 16 GB RAM minimal 64 GB RAM maksimal 51
Konektor (Per Papan Sistem) Belakang NIC Dua buah RJ-45 (10/100/1000 Mbps Ethernet) Seri 9-pin, DTE, 16550-compatible USB Dua buah 4-pin, USB 2.0-compliant Video 15-pin D-Sub VGA Lubang manajemen Lubang Ethernet tersendiri untuk akses manajemen jarak jauh Video (Per Papan Sistem) Jenis video On-board AST2050 video controller Memori video 8 MB Daya Pencatu daya AC (per pencatu daya) Watt 1023 W jaringan rendah/1100 W jaringan tinggi Voltase 100-240 V CA, 50-60 Hz, arus input maksimum: 12.
Fisik Tinggi 8,76 cm (8,76 cm) Lebar 44,8 cm (44,70 cm) Panjang 79,0 cm (31,1 in) Bobot (konfigurasi maksimum) 42 kg (42,01 kg) Bobot (kosong) 16,5 kg (16,50 kg) Lingkungan CATATAN: Untuk informasi tambahan mengenai tolok ukur lingkungan untuk konfigurasi sistem tertentu, lihat www.dell.com/environmental_datasheets.
Guncangan maksimum Operasional Satu pulsa guncangan pada sumbu z positif (satu pulsa pada setiap sisi sistem) sebesar 31 G selama 2,6 mdet di dalam orientasi operasional Penyimpanan Enam pulsa guncangan berturut-turut pada sumbu x, y, dan z positif dan negatif (satu pulsa pada setiap sisi sistem) sebesar 71 G selama maksimum 2 mdet; Enam pulsa guncangan berturut-turut pada sumbu x, y, dan z positif dan negatif (satu pulsa pada setiap sisi sistem) sebesar 22 G pulsa gelombang persegi biasa dengan perubaha
Dell PowerEdge C6145 はじめに
メモ、注意、警告 メモ:コンピュータを使いやすくするための重要な情報を説明しています。 注意:手順に従わないと、ハードウェアの損傷やデータの損失につながる可能 性があることを示しています。 警告:物的損害、けが、または死亡の原因となる可能性があることを示してい ます。 ______________ 本書の内容は予告なく変更されることがあります。 © 2011 すべての著作権は Dell Inc. にあります。 Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じら れています。 本書に使用されている商標:Dell™、DELL ロゴ、および PowerEdge™ は Dell Inc. の商標です。AMD® は Advanced Micro Devices, Inc. の登録商標です。AMD Opteron™ は Advanced Micro Devices, Inc. の商標です。Red Hat Enterprise Linux® および Enterprise Linux® は米国その他の国における Red Hat, Inc.
警告:立入制限区域 このサーバーは、IEC 60950-1: 2001 の Cl. 1.2.7.
1 レールラッチを開くには、エンドピースの中央にあるラッチ リリースボタンを引きます。 2 レールのエンドピースを垂直ラックフランジに合わせ、ペグ を 1 番目の U の最下部の穴と 2 番目の U の最上部の穴に入れ ます。ラッチが所定の位置にロックされるまで、レールの後 端をはめ込みます。 メモ:レールは角型穴(下図の 1)と丸型穴(下図の 2)の両方のラックに 使用できます。 コンピュータの背面 正面 3 手順 1 と手順 2 を繰り返して、前面のエンドピースを垂直フ ランジに取り付けます。 メモ:レールを取り外すには、エンドピースの中央にあるラッチリリース ボタンを引いて各レールを外します。 4 はじめに 背面の各垂直ラックフランジで、レールのすぐ上にある 2 つ の角穴に 2 つのねじ込み口金を差し込みます。 | 48
5 シャーシスタビライザシッピングブラケット(オプション) を背面のラックフランジに取り付け、同時にネジを締めます。 メモ:ラックに取り付け済みのシステムを移動する場合は、2 つのシャー シスタビライザシッピングブラケット(オプション)が取り付けられてい ることを確認してください。 コンピュータの背面 6 システムをラックに挿入します。 はじめに | 49
7 蝶ネジを締めて、システムの両側をラックフランジの前面に 固定します。 コンピュータの背面 正面 はじめに | 50
オプション — キーボード、マウス、モニターの接続 キーボード、マウス、モニター(オプション)を接続します。 システム背面のコネクタには、どのケーブルをどのコネクタに接続する かを示すアイコンがあります。モニターのケーブルコネクタにネジがあ る場合は、必ず締めてください。 はじめに | 51
電源ケーブルの接続 システムの電源ケーブルをシステムに接続し、モニターを使用する場合 は、モニターの電源ケーブルをモニターに接続します。電源ケーブルの もう一方の端をアースされたコンセントまたは無停電電源装置や配電装 置などの別の電源に接続します。 はじめに | 52
システムの電源投入 システムとモニターの前面または背面にある電源ボタンを押します。電 源インジケータが点灯します。 はじめに | 53
OS のセットアップの完了 OS を初めてインストールする場合は、お使いの OS のインストールと 設定に関するマニュアルを参照してください。システムとは別途に購入 したハードウェアやソフトウェアのインストールは、OS がインストー ル済みであることを確認してから行ってください。 対応 OS Microsoft Windows HPC Server 2008 R2(64 ビット) Microsoft Windows Server 2008 Core R2(64 ビット) Microsoft Windows Server 2008 R2 Hyper-V Microsoft Windows Server 2008 R2 Enterprise(64 ビット) Red Hat Enterprise Linux 5.5(64 ビット) Red Hat Enterprise Linux 6.0(認証のみ) SUSE Linux Enterprise Server 11 SP1(64 ビット) VMware ESX Server 4.
その他の情報 警告:システムに付属のマニュアルで安全および認可機関に関する情報を参照して ください。保証情報は、このマニュアルに含まれている場合と、別の文書として付 属する場合があります。 『ハードウェアオーナーズマニュアル』では、システムの機能、トラブルシュ ーティングの方法、およびコンポーネントの取り付け方や交換方法について説 明しています。この文書は support.dell.com/manuals から入手できます。 Dell システム管理アプリケーションのマニュアルでは、システム管理ソ フトウェアのインストール方法と使い方を説明しています。この文書は support.dell.com/manuals からオンラインで入手できます。 メモ:アップデートには他の文書の内容を差し替える情報が含まれている 場合がよくありますので、support.dell.
仕様 プロセッサ(各システム基板につき) プロセッサのタイプ AMD Opteron 6100 シリーズのプロセッ サ4個 拡張バス(各システム基板につき) PCI Express Generation 2 バスのタイプ 拡張スロット PCIe ドーターカード PCIe ロープロファイル x16 スロット 1 個 ハーフレングス / ハーフハイト x16 ス ロット 2 個 x16 メザニンスロット 1 個 メモリ(各システム基板につき) アーキテクチャ DDR3 1066/1333 MHz RDIMM または UDIMM 32 枚 メモリモジュールソケット メモリモジュールの容量 最小 RAM 最大 RAM x DDR3 DIMM ソケット 32 個 2 GB、4 GB、8 GB、または 16 GB 64 GB 512 GB ドライブ ハードドライブ ホットスワップ対応の 3.5 インチ SAS/SATA ドライブ 12 台まで、ま たはホットスワップ対応の 2.
コネクタ(各システム基板につき) 背面 NIC シリアル USB ビデオ 管理ポート RJ-45(10/100/1000 Mbps イーサネ ット)コネクタ 2 個 16550 互換 9 ピン DTE 4 ピン USB 2.0 対応コネクタ 2 個 15 ピン D サブ VGA リモート管理アクセス専用イーサネッ トポート ビデオ(各システム基板につき) ビデオのタイプ オンボード AST2050 ビデオコント ローラ ビデオメモリ 8 MB 電源 AC 電源ユニット(各電源ユニットにつき) ワット数 1023 W 低ライン /1100 W 高ライン 電圧 100 ~ 240 V CA、50/60 Hz、最大入 力電流:12.0 A 熱消費 最大 4217.063 BTU/ 時 ワット数 1400 W 電圧 200 ~ 240 V CA、50/60 Hz、最大入 力電流:8.
バッテリー(各システム基板につき) システムバッテリー 3.0 V コイン型リチウムイオンバッ テリー CR 2032 RAID バッテリー(オプショ ン) 3.7 V リチウムイオンバッテリーパ ック サイズと重量 縦幅 8.76 cm 横幅 44.8 cm 奥行き 79.0 cm 重量(最大構成) 42 kg 重量(空の状態) 16.5 kg 環境 メモ:特定のシステム構成でのその他の環境条件の詳細については、 www.dell.
最大振動 動作時 保管時 5 ~ 350 Hz で 0.26 Grms 15 分間にわたり 10 ~ 500 Hz で 1.88 Grms 最大衝撃 動作時 保管時 z 軸の正方向に 2.6 ミリ秒で 31 G の 1 衝撃パルス(システムの各面に対して 1 パルス) x、y、z 軸の正および負方向に 6 連続衝 撃パルス(システムの各面に対して 1 パルス)、2 ミリ秒以下で 71 Gx、y、z 軸の正および負方向に 6 連続衝撃パル ス(システムの各面に対して 1 パル ス)、22 G フェアードスクエアパルス 波(508 cm / 秒の速度変化) 高度 動作時 –16 ~ 3,048 m メモ:高度が 900 m を超えると、動作時の許容 最大温度は、302 m ごとに 1 °C ずつ低下し ます。 保管時 –16 ~ 10,600 m 空気中浮遊汚染物質レベル クラス G2 またはそれ未満 (ISA-S71.
はじめに | 60
Dell PowerEdge C6145 시스템 시작 안내서
주, 주의 및 경고 주: "주"는 시스템을 보다 효율적으로 사용하는 데 도움을 주는 중요 정보를 제공합니다. 주의: "주의"는 지침을 준수하지 않을 경우의 하드웨어 손상이나 데이터 손실 위험을 설명합니다. 경고: "경고"는 재산상의 피해나 심각한 부상 또는 사망을 유발할 수 있는 위험이 있음을 알려줍니다. ______________ 이 발행물에 수록된 정보는 사전 통보 없이 변경될 수 있습니다. © 2011 Dell Inc. 저작권 본사 소유. Dell Inc.의 서면 승인 없이 어떠한 방식으로든 본 자료를 무단 복제하는 행위는 엄격히 금지됩니다. 본 설명서에서 사용된 상표인 Dell™, DELL 로고 및 PowerEdge™는 Dell Inc.의 상표입니다. AMD®는 등록 상표이고 AMD Opteron™은 Advanced Micro Devices, Inc.의 상표입니다.
주의: 제한 접근 지역 본 서버는 다음 두 조건이 적용되는 IEC 60950-1: 2001 의 Cl. 1.2.7.3 에 정의된 제한 접근 지역에서만 설치하도록 고안되었습니다. 해당 지역에 적용되는 제한 사유 및 취해야 할 모든 예방 조치 에 관해 지도를 받은 서비스 기술자 또는 사용자만 액세스할 수 있습니다. 접근은 도구, 잠금 및 키 또는 다른 보안 수단을 사용하여 이루어지며, 지역 담당 책임자에 의해 제어됩니다. 설치 및 구성 경고: 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토하십시오. 시스템 포장 풀기 시스템 포장을 풀고 각 항목을 확인합니다. 도구를 사용하지 않은 레일 솔루션 설치 경고: 시스템을 들어야 하는 경우에는 도움을 청합니다. 부상당할 우려가 있으므로 시스템을 혼자 들지 마십시오. 경고: 시스템은 랙에 고정되거나 레일에 장착되어 있지 않습니다. 부상이나 시스템 손상을 방지하려면 설치 또는 제거 시 시스템을 적절한 방법으로 지지해야 합니다.
1 끝 부분 중간 지점에 있는 래치 분리 단추를 당겨 레일 래치를 엽니다. 2 레일의 끝 부분을 수직 랙 플랜지에 맞추어 첫 번째 U 의 아래쪽 구멍 및 두 번째 U 의 위쪽 구멍에 페그를 장착합니다. 래치가 제자리에 고정될 때까지 레일의 뒤쪽 끝을 고정합니다. 주: 레일은 사각 구멍 랙(아래 그림의 항목 1) 및 원형 구멍 랙(아래 그림의 항목 2) 모두에서 사용될 수 있습니다. 후면 보기 전면 보기 3 1 단계 및 2 단계를 반복하여 수직 플랜지에 앞쪽 끝 부분을 맞춰 장착합니다. 주: 레일을 분리하려면 끝 부분 중간 지점에 있는 분리 래치 단추를 당겨 각 레일을 분리합니다. 4 뒤쪽의 각 수직 랙 플랜지에서 레일 바로 위에 있는 두 개의 사각 구멍에 나사 베이스 두 개를 삽입합니다. 5 섀시 고정 장치 운송 브래킷(선택 사양)을 뒤쪽 랙 플랜지에 설치하면서 동시에 나사를 조입니다.
후면 보기 6 시스템을 랙에 밀어 넣습니다. 7 나비 나사를 조여 시스템 모서리를 랙 플랜지 전면에 고정합니다.
선택적 단계 – 키보드, 마우스 및 모니터 연결 키보드, 마우스 및 모니터를 연결합니다(선택적). 시스템 후면에 있는 커넥터에는 각 커넥터에 연결될 케이블이 표시된 아이콘이 있습니다. 모니터의 케이블 커넥터에 있는 나사(있는 경우)를 단단히 고정합니다.
전원 케이블 연결 시스템의 전원 케이블을 시스템에 연결하고, 모니터를 사용하는 경우 모니터의 전원 케이블을 모니터에 연결합니다. 전원 케이블의 반대쪽 끝을 접지된 전원 콘센트나 무정전 전원 공급 장치 또는 배전 장치와 같은 별도의 전원에 연결합니다.
시스템 켜기 시스템의 전면 또는 후면이나 모니터에 있는 전원 단추를 누릅니다. 그러면 전원 표시등이 켜집니다.
운영 체제 설치 완료 운영 체제를 처음 설치하려면 운영 체제에 대한 설치 및 구성 설명서를 참조하십시오. 시스템과 함께 구입하지 않은 하드웨어 또는 소프트웨어를 설치하기 전에 운영 체제가 설치되어 있는지 확인하십시오. 지원되는 운영 체제 Microsoft Windows HPC Server 2008 R2(64 비트) Microsoft Windows Server 2008 Core R2(64 비트) Microsoft Windows Server 2008 R2 Hyper-V Microsoft Windows Server 2008 R2 Enterprise(64 비트) Red Hat Enterprise Linux 5.5(64 비트) Red Hat Enterprise Linux 6.0(인증 전용) SUSE Linux Enterprise Server 11 SP1(64 비트) VMware ESX Server 4.
기타 필요한 정보 경고: 시스템과 함께 제공된 안전 및 규제 정보를 참조하십시오. 보증 정보는 본 설명서에 포함되어 있거나 별도의 문서로 제공됩니다 하드웨어 소유자 매뉴얼에서는 시스템 기능에 대한 정보를 제공하고 시스템 문제 해결 방법 및 시스템 구성요소 설치 또는 교체 방법을 설명합니다. 이 문서는 support.dell.com/manuals 에서 볼 수 있습니다. Dell 시스템 관리 응용프로그램 설명서에서는 시스템 관리 소프트웨어를 설치하고 사용하는 방법에 대한 정보를 제공합니다. 이 문서는 support.dell.com/manuals 에서 온라인으로 볼 수 있습니다 주: 새로운 업데이트가 없는지 support.dell.com/manuals 에서 항상 확인하십시오. 업데이트에는 최신 정보가 수록되어 있으므로 다른 문서를 읽기 전에 반드시 먼저 참조하시기 바랍니다.
기술 사양 프로세서(시스템 보드당) 프로세서 종류 AMD Opteron 6100 시리즈 프로세서 4개 확장 버스(시스템 보드당) 버스 종류 PCI Express Generation 2 확장 슬롯 PCIe x16 1 개, 로우 프로파일 x16 2 개, 절반 길이/절반 높이 도터 카드 PCIe x16 1 개, 메자닌 슬롯 메모리(시스템 보드당) 아키텍처 32 x DDR3 1066/1333MHz RDIMM 또는 UDIMM 메모리 모듈 소켓 32 x DDR3 DIMM 소켓 메모리 모듈 용량 2GB, 4GB, 8GB 또는 16GB 최소 RAM 64GB 최대 RAM 512GB 드라이브 하드 드라이브 3.5 인치 핫 스왑 가능 SAS/SATA 드라이브 최대 12 개 또는 2.5 인치 핫 스왑 가능 SAS/SATA/SSD 드라이브 최대 24 개 주: SAS 하드 드라이브는 추가 카드로 지원됩니다.
커넥터(시스템 보드당) 후면 NIC RJ-45(10/100/1000Mbps 이더넷) 2 개 직렬 9 핀, DTE, 16550 호환 USB 4 핀 2 개, USB 2.0 호환 비디오 15 핀 D-Sub VGA 관리 포트 원격 관리 액세스 전용 이더넷 포트 비디오(시스템 보드당) 비디오 종류 온보드 AST2050 비디오 컨트롤러 비디오 메모리 8MB 전원 AC 전원 공급 장치(전원 공급 장치당) 1023W 저전압/1100W 고전압 와트 100-240V CA, 50-60Hz, 최대 입력 전류: 12.0Amps 전압 최대 4217.063BTU/hr 열 손실 1400W 와트 200-240V CA, 50-60Hz, 최대 입력 전류: 8.6Amps 전압 최대 5724BTU/hr 열 손실 초기 유입 전류는 55Amps(피크)를 초과할 수 없습니다. 이차 유입 전류는 35Amps(피크)를 초과할 수 없습니다. 최대 유입 전류 전지(시스템 보드당) CR 2032 3.
규격 높이 8.76cm(3.45 인치) 너비 44.8cm(17.6 인치) 깊이 79.0cm(31.1 인치) 무게(최대 구성 시) 42kg(92.61lb) 무게(비어 있을 경우) 16.5kg(36.38lb) 환경적 특성 주: 특정 시스템 구성을 위한 환경 측정에 대한 자세한 내용은 www.dell.com/environmental_datasheets 를 참조하십시오. 온도 작동 시 10°~35°C(50°~95°F), 시간당 최고 10°C 의 온도 변화 기준 주: 900 미터 이상의 고도에서는 최대 작동 온도가 300 미터당 1°C 씩 감쇄됩니다. 보관 시 –40° ~ 65°C(–40° ~ 149°F),시간당 최고 20°C 의 온도 변화 기준 상대 습도 작동 시 20% ~ 80%(비응축),시간당 최고 10%의 습도 변화 기준 보관 시 5% ~ 95%(비응축) 최대 진동 작동 시 5 ~ 350Hz 에서 0.26Grms 보관 시 10~500Hz 에서 15 분 동안 1.
최대 충격 작동 시 작동 방향으로 2.6ms 동안 (+) z 축으로 31G 의 충격 펄스 1 회(시스템 각 면에 1 회의 펄스) 최대 2ms 동안 (+/-) x, y, z 축으로 71G 의 연속 충격 펄스 6 회(시스템 각 면에 1 회의 펄스) 보관 시 속도 변화가 508cm/초(200 인치/초)인 22G 구형파의 (+/-) x, y, z 축으로 연속 충격 펄스 6 회(시스템 각 면에 1 회의 펄스) 고도 -16 ~ 3,048m(-50 ~ 10,000ft) 작동 시 주: 900 미터 이상의 고도에서는 최대 작동 온도가 300 미터당 1°C 씩 감쇄됩니다. -16 ~ 10,600 m(-50 ~ 35,000 ft) 보관 시 공기 중 오염 물질 수준 ISA-S71.