User Manual

This command is applicable only in PMUX mode.
3. Add the interface to the second port channel.
INTERFACE PORT-CHANNEL mode
channel-member interface
Example of Moving an Interface to a New Port Channel
The following example shows moving the TenGigabitEthernet 0/8 interface from port channel 4 to port
channel 3.
Dell(conf-if-po-4)#show config
!
interface Port-channel 4
channel-member TenGigabitEthernet 0/8
no shutdown
Dell(conf-if-po-4)#no chann tengi 0/8
Dell(conf-if-po-4)#int port 3
Dell(conf-if-po-3)#channel tengi 0/8
Dell(conf-if-po-3)#sho conf
!
interface Port-channel 3
channel-member TenGigabitEthernet 0/8
shutdown
Dell(conf-if-po-3)#
Configuring the Minimum Oper Up Links in a Port Channel
You can configure the minimum links in a port channel (LAG) that must be in “oper up” status to consider
the port channel to be in “oper up” status.
To set the “oper up” status of your links, use the following command.
Enter the number of links in a LAG that must be in “oper up” status.
INTERFACE mode
minimum-links number
The default is 1.
Example of Configuring the Minimum Oper Up Links in a Port Channel
Dell#config t
Dell(conf)#int po 128
Dell(conf-if-po-128)#minimum-links 5
Dell(conf-if-po-128)#
Configuring VLAN Tags for Member Interfaces
To configure and verify VLAN tags for individual members of a port channel, perform the following:
1. Configure VLAN membership on individual ports
INTERFACE mode
124