User Manual

offset: (OPTIONAL) Enter the number of minutes to add during the summer-time period. The
range is from 1 to1440. The default is 60 minutes.
Example of the clock summer-time recurring Command
Dell(conf)#clock summer-time pacific recurring Mar 14 2012 00:00 Nov 7 2012
00:00
Dell(conf)#
NOTE: If you enter <CR> after entering the recurring command parameter, and you have already
set a one-time daylight saving time/date, the system uses that time and date as the recurring
setting.
Example of Clock Summer-Time Recurring Parameters
Dell(conf)#clock summer-time pacific recurring ?
<1-4> Week number to start
first Week number to start
last Week number to start
<cr>
Dell(conf)#clock summer-time pacific recurring
Dell(conf)#
VLAN Configuration on Physical Ports and Port-Channels
Unlike other Dell Networking OS platforms, IOA allows VLAN configurations on port and port-channel
levels. This allows you to assign VLANs to a port/port-channel.
NOTE: In PMUX mode, in order to avoid loops, only disjoint VLANs are allowed between the uplink
ports/uplink LAGs and uplink-to-uplink switching is disabled.
1. Initialize the port with configurations such as admin up, portmode, and switchport.
Dell#configure
Dell(conf)#int tengigabitethernet 0/1
Dell(conf-if-te-0/1)#no shutdown
Dell(conf-if-te-0/1)#portmode hybrid
Dell(conf-if-te-0/1)#switchport
2. Configure the tagged VLANs 10 through 15 and untagged VLAN 20 on this port.
Dell(conf-if-te-0/1)#vlan tagged 10-15
Dell(conf-if-te-0/1)#vlan untagged 20
Dell(conf-if-te-0/1)#
3. Show the running configurations on this port.
Dell(conf-if-te-0/1)#show config
!
interface TenGigabitEthernet 0/1
portmode hybrid
switchport
vlan tagged 10-15
vlan untagged 20
no shutdown
Dell(conf-if-te-0/1)#end
Dell#
234
PMUX Mode of the IO Aggregator