User Manual

Step Task Command Command Mode
1
Configure a server-facing Ethernet port or
port channel with an FCoE map.
interface
{tengigabitEthernet
slot/port | port-
channel num}
CONFIGURATION
2
Apply the FCoE/FC configuration in an FCoE
map on the Ethernet port. Repeat this step to
apply an FCoE map to more than one port, for
example:
Dell# interface tengigabitEthernet
0/0
Dell(config-if-te-0/0)# fcoe-map
SAN_FABRIC_A
Dell# interface port-channel 3
Dell(config-if-te-0/0)# dcb-map
SAN_DCB1
Dell(config-if-po-3)# fcoe-map
SAN_FABRIC_A
Dell# interface
fortygigabitEthernet 0/48
Dell(config-if-fo-0/0)# fcoe-map
SAN_FABRIC_A
fcoe-map map-name
INTERFACE or
INTERFACE
PORT_CHANNEL
3
Enable the port for FCoE transmission using
the map settings.
no shutdown
INTERFACE
Applying an FCoE Map on Fabric-facing FC Ports
The Aggregator, with the FC ports, are configured by default to operate in N port mode to connect to an
F port on an FC switch in a fabric. You can apply only one FCoE map on an FC port.
When you apply an FCoE map on a fabric-facing FC port, the FC port becomes part of the FCoE fabric,
whose settings in the FCoE map are configured on the port and exported to downstream server CNA
ports.
Each Aggregator, with the FC port, is associated with an Ethernet MAC address (FCF MAC address). When
you enable a fabric-facing FC port, the FCoE map applied to the port starts sending FIP multicast
advertisements using the parameters in the FCoE map over server-facing Ethernet ports. A server sees the
FC port, with its applied FCoE map, as an FCF port.
Step Task Command Command Mode
1
Configure a fabric-facing FC port.
interface
fibrechannel slot/
port
CONFIGURATION
2
Apply the FCoE and FC fabric configurations in
an FCoE map to the port. Repeat this step to
apply an FCoE map to more than one FC port,
for example:
Dell# interface fi 0/9
Dell(config-if-fc-0/9)# fabric
SAN_FABRIC_A
fabric
map-name
INTERFACE
FIBRE_CHANNEL
258