User Manual

U 1
T 2-4094
Native VlanId: 1
2. Assign the port to a specified group of VLANs (vlan tagged command) and re-display the port mode
status..
Dell(conf)#interface tengigabitethernet 0/1
Dell(conf-if-te-0/1)#vlan tagged 2-5,100,4010
Dell(conf-if-te-0/1)#
Dell#show interfaces switchport tengigabitethernet 0/1
Codes: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
G - GVRP tagged, M - Trunk, H - VSN tagged
i - Internal untagged, I - Internal tagged, v - VLT untagged, V -
VLT tagged
Name: TenGigabitEthernet 0/1
802.1QTagged: Hybrid
SMUX port mode: Admin VLANs enabled
Vlan membership:
Q Vlans
U 1
T 2-5,100,4010
Native VlanId: 1
Software show Commands
Use the show version and show system stack-unit 0 commands as a part of troubleshooting an
Aggregator’s software configuration.
Table 28. Software show Commands
Command Description
show version Display the current version of Dell Networking OS software
running on an Aggregator.
show version Command Example
Dell#show version
Dell Real Time Operating System Software
Dell Operating System Version: 2.0
Dell Application Software Version: 9-4(0-180)
Copyright (c) 1999-2014 by Dell Inc. All Rights Reserved.
Build Time: Sun Mar 30 20:15:19 PDT 2014
Build Path: /work.local/build/toolSpaces/tools05/E9-4-0/SW/SRC
Dell Networking OS uptime is 9 hour(s), 21 minute(s)
System image file is "dv-ci-stomp-tc-1-a1"
System Type: PE-FN-410S-IOA
Control Processor: MIPS RMI XLP with 2147483648 bytes of memory, core(s) 1.
128M bytes of boot flash memory.
1 12-port GE/TE (FN)
Debugging and Diagnostics
269