Table 8. DC PSU status indicator codes (continued)
Power indicator codes Condition
CAUTION: When correcting a PSU mismatch, replace only the PSU with the
blinking indicator. Swapping the PSU to make a matched pair can result in an
error condition and unexpected system shutdown. To change from a High Output
configuration to a Low Output configuration or vice versa, you must turn off the
system.
CAUTION: If two PSUs are used, they must be of the same type and have the same
maximum output power.
CAUTION: Combining AC and DC PSUs is not supported and triggers a mismatch.
Non-redundant power supply unit indicator codes
Press the self-diagnostic button to perform a quick health check on the non-redundant power supply unit (PSU) of the system.
Figure 6. Non-redundant AC PSU status indicator and self-diagnostic button
1. Self-diagnostic button
2. AC PSU status indicator
Table 9. Non-redundant AC PSU status indicator
Power Indicator Pattern Condition
Not lit Power is not connected or PSU is faulty.
Green A valid power source is connected to the PSU and the PSU is operational.