Owners Manual

Table 1. Left control panel - LED indicator description
Indicator Description Status
1 System health Blinks amber for 2 seconds and is OFF for 1 second when the chassis health has degraded. By
default, the LED is unlit.
2 System
temperature
Blinks amber for 2 seconds and is OFF for 1 second when a thermal fault exists on the enclosure. By
default, the LED is unlit.
NOTE: A thermal fault includes excessive ambient temp, I/O modules thermal status,
PSU thermal status, and fan status.
3 I/O module health Blinks amber for 2 seconds and is OFF for 1 second when an I/O module is faulty. By default the
LED is unlit.
4 Fan health Blinks amber for 2 seconds and is OFF for 1 second when a front or rear mounted fan fails or has a
warning. By default, the LED is unlit.
5 Stack or group Indicates that the enclosure is a member of a group.
6 LED status bar Indicator status Description
Solid blue Indicates that the enclosure is healthy.
Blinking blue Indicates that the system ID mode is active.
Blinking amber Indicates that the system is experiencing a fault.
7 System ID button Allows you to identify the system or the installed sleds.
Figure 5. Left control panel - LCD options
Table 2. Left control panel - LCD panel description
Indicator Description Status
1 LCD with Quick
Sync
LCD enabled with Quick Sync module
2 LCD without Quick
Sync
LCD without Quick Sync module
3 System ID
indicator on LCD
panel
This option is a button/indicator on the LCD panel to identify the chassis, or choose specific sleds to
identify.
4 Settings This option button provides access to the inventory and configuration data of the MX7000
enclosure. It includes the Network Settings, System Information, (Model, Asset Tag, Service Tag),
and Language Settings.
5 Optional
QuickSync
indicator (Only for
Enables access to QuickSync related controls and connection information.
Enclosure overview 13