Owners Manual

Table 9. KVM supported RACADM commands(continued)
Command Description
debug
Enables the debug authorization commands.
deploy
Deploys the blade or IOM with specified properties.
faultlist
Displays the active messages in the chassis subsystem.
getniccfg
Displays the current network settings.
getsensorinfo
Displays the system sensor information.
getsysinfo
Displays the general management module and system information.
getpminfo
Displays the power management status information.
getpbinfo
Displays the power budget status information.
racreset
Performs a management module reset operation.
racresetcfg
Performs a management module factory reset operation.
swinventory
Displays the list of software's installed on the chassis.
serveraction
Perform a server or storage power management operation.
setniccfg
Modify the network configuration properties.
traceroute
Displays the route packets trace to network host.
traceroute6
Displays the IPv6 route packets trace to network host.
ifconfig
Displays the network interface information.
ping
Sends ICMP echo packets on the network.
ping6
Sends IPv4 ICMP echo packets on the network.
getconfig
Displays the management module configuration properties.
config
Modify the management module configuration properties.
chassisgroup
Enables multiple chassis management.
KVM limitations
The KVM features are disabled in the following scenarios:
If the iDRAC is undergoing a reset process.
If the management module is undergoing a reset process or not active.
The OSD is blank until the management module is active.
DP - DVI and DP - HDMI are not supported by the PowerEdge MX7000 KVM solution.
The maximum resolution that is supported by the PowerEdge MX7000 are:
1920 x 1200, 32 bits per pixel @ 60 Hz
1600 x 1200, 32 bits per pixel @ 75 Hz
For more information about the PowerEdge MX7000 at the box serial access feature of the chassis management firmware , see
PowerEdge MX7000 At-the-Box Serial Access to Management Firmware
For more information about the PowerEdge MX7000 supported RACADM Commands, see Dell EMC OpenManage Enterprise Modular
Edition Version 1.00.01 for PowerEdge MX7000 Chassis
Initial system setup and configuration