Owners Manual
Fabrics and modules
There are several connections on the Main Distribution Board to enable communication between the IOMs. Between each pair of IOMs
(C1 and C2), there is a link for intermodule communication. This link is referred as Fabric-V in the schematics. This link supports a x1
connection with each lane operating up to 10 Gbps per direction. In addition to the Fabric-V, there are handshake signals between the two
modules to facilitate redundancy/failover or other module to module communication. The usage of these interconnects depends on the
IOM design and its particular requirements.
There are three fabrics connections available in MX7000 enclosure.
• General purpose (2) - Fabric A and B
• Storage (1) - Fabric C
• Fabric module A or B
• Fabric module C
• Management module
Removing a blank from Fabric A or B slot
Steps
1. Press the blue release button to release the blank.
2. Pull the blank out of the enclosure.
NOTE: To maintain proper airflow, ensure that the blanks are installed if the IOMs are not installed.
Figure 28. Removing a blank from Fabric A or B slot
Next steps
1. Install a module in the Fabric A or B slot or a blank.
Installing a blank in Fabric A or B slot
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
Installing and removing system components
39