Users Guide
For steps to upgrade from different versions, see the sections, Upgrading from 10.5.0.5 and Upgrading from versions earlier
than 10.5.0.5.
7. Go to Monitoring > Jobs page, to view the job status.
Upgrading from 10.5.0.5
● When updating, ensure to update the IOMs in groups no larger than four per upgrade job.
● If there are two switches in a full-switch mode VLT, each switch should be part of different upgrade batch for redundancy.
● If there are two switches in a SmartFabric, select only one switch. The other switch is automatically updated. This is counted
as "2" in that upgrade group.
Upgrading from versions earlier than 10.5.0.5
● When updating, ensure to update the IOMs in groups no larger than four per upgrade job.
● If there are two switches in a full-switch mode VLT, each switch must be part of different upgrade batch for redundancy.
● If there are two switches in a SmartFabric, select only one switch. The other switch is automatically updated and is counted
as "2" in that upgrade group.
● Upgrade Master or its peer fabric IOM in last group.
To identify the master IOM:
1. Log in to any IOM switch
2. Go to linux prompt using the commands:
a. system bash
b. sudo -i
3. Go to the SmartFabric Services CLI prompt using the command:
python /opt/dell/os10/bin/rest-service/tool/dnv_cli.py
4. Get the Master IOM service tag using below command:
show cluster
16
Updating the management module firmware