Users Guide

Configuring OMEModular date and time settings
1. Click Application Settings > Network > Time Configuration.
2. Select the Use NTP check box, if required, and enter the NTP server details.
3. Select the required time zone.
NOTE: Any change in the attribute settings leads to IP drop or unavailability of the OMEModular web interface for
some time. However, the OMEModular web interface recovers automatically.
Configuring OMEModular proxy settings
1. Click Application Settings > Network > Proxy Configuration.
2. Select Enable HTTP Proxy Settings.
3. Enter the proxy address and the port number.
4. If the proxy requires authentication, select Enable Proxy Authentication and enter the credentials.
You can enable proxy authentication only if the Enable HTTP Proxy Settings option is selected.
5. Enter the proxy user credentials.
Configuring IOM synchronization
You can replicate the time and alert destination configuration of the lead chassis in the network and FC IOMs.
To configure the time and alert destination:
1. Click Application Settings > Network > IOM Synchronization Configuration.
2. Select the Replicate Time Configuration from Chassis and Replicate Alert Destination Configuration from Chassis
check boxes.
MXG610s supports only three SNMP destination unlike OS10 which supports four SNMP destinations.
Using SNMP, IPV4 and IPV6 replication is supported from OME-Modular to IOM.
Using SNMP, FQND and Host Name is supported only if DNS Address for FC IOM (Pre-requisite for DNS
configuration) is Static management IP Address configuration.
Using SNMP, SNMPV2 replication is supported for OS10 and SNMPV1 replication is supported for FC IOM.
MXG610s supports four Syslog destinations same as MSM.
Using Syslog, only 514-port number is supported from MSM to Network IOM.
Using Syslog, 10 to 65535-port number is supported from MSM to FC IOM. Port number is configured as a secure
port.
3. Click Apply to save the changes.
In MCM environment, the IOM network synchronization configuration is propagated from the lead to the member chassis
only if the time and alert destination options are selected while creating the chassis group or adding members to the group.
Changing device naming and preference
1. Click Application Settings > Network > Device Name Preference.
2. Select the naming preference.
Ports and protocols supported in OME-Modular
The table below lists the protocols and ports that are supported in OME-Modular.
44
Logging in to OME-Modular