Users Guide

NOTE: Do not use "system" as a user name.
4. Enter the Password and Confirm Password.
The password can be 8-32 characters long and contain at least one of the following:
Number
Special characterThe supported special characters are - +, &, ?, >, -, }, |, ., !, (, ', ,, _, [, ", @, #, ), *, ;, $, ], /, %, =,
<, :, {, I
Uppercase letter
Lowercase letter
5. Select a role.
6. Select Enabled to enable the account immediately after you create it.
NOTE: For more information about the fields, see the integrated help in the OMEModular web interface.
Enabling, disabling, and deleting users
1. Click Application Settings > Users.
A list of user account is displayed.
2. Select the account, and then click the required option above the list of accounts.
Recovering passwords
You must have physical access to the chassis to reset the login credentials to defaults.
Recovering passwords in single OME-Modular controller
1. From the chassis, remove the single OMEModular controller.
2. Locate the Jumper, see the board locationP57 RESET PASSWORD, and then insert the Jumper.
3. Reinsert the controller into the chassis.
4. When OMEModular is available, login with the user name as "root" and password as "calvin".
5. After the root user authentication, change the password for the root user on the Application Settings > Users page.
6. Log out and log in again using the modified password to ensure that the login is successful.
7. Remove the jumper and reinsert it into the default positions2 and 3.
Recovering passwords in dual OME-Modular controllers
1. From the chassis, remove both the OME-Modular controllers.
2. On one of the modules, locate the Jumper, see the board locationP57 RESET PASSWORD, and then insert the Jumper.
3. Reinsert only the controller, where the Jumper is installed, into the chassis.
4. When OMEModular is available, login with the user name as "root" and password as "calvin".
5. After the root user authentication, modify the password for the root user on the Application Settings > Users page.
6. Remove the controller where the Jumper is inserted, locate the Jumper.
7. Set the Jumper to the default position and insert the controller back into the chassis.
8. When OME-Modular is available, login with the modified password.
9. Insert the second controller to restore the MM redundancy.
Logging in to OME-Modular
47