Users Guide

1. From the Devices drop-down menu, select Storage.
2. Select the storage sled.
3. Click Blink LED and click Turn On.
To turn off the LED blinking:
1. From the Devices drop-down menu, select Storage.
2. Select the storage sled.
3. Click Blink LED and click Turn Off.
You can pull out the storage sled trays from the chassis to access the storage sled drives. When a tray is opened, the storage
sled drive is away from the chassis and does have cooling support causing the temperature of the drive to reach a critical level.
When the tray is opened, the LCD displays count down timer starting from five minutes. Close the tray within five minutes for
cooling the storage drive. Also, if another tray containing a storage sled drive is opened, the current warning display is not
affected. You can dismiss the LCD warning display.
NOTE: The LCD display for storage-mapping owing to server replacement takes priority over opening of the storage tray. If
LCD has completed displaying storage-mapping menus and a storage tray is still open, a warning, stating the storage tray is
open, is displayed.
Editing storage sled assignments
You can change the assignments of the device using Edit Assignments option. To edit assignments:
On the storage Overview page, click Edit Assignments.
The Hardware page is displayed.
Select the hardware component, and change the assignment. For more information, see Assigning drives to a compute sled.
Other information
On the Hardware page, you can view more information about the device as follows:
Storage Enclosure InformationProvides the information of an enclosure, such as Name, FQDD, Model, Service Tag,
Asset Tag, Power State, Firmware Version, Drive Slot Count, and Assignment Mode
Chassis InformationProvides the information of a chassis, such as Chassis, Slot Name, and Slot
Connected I/O Module InformationProvides the information of an I/O module such as I/O Module Name and
Multipath
Recent AlertsProvides the list of the recent alerts
Recent ActivityProvides the list of recent activities
Storage SubsystemsProvides the list of storage subsystem
EnvironmentProvides the information of the power usage
Viewing hardware details
The hardware components of a storage sled consist of hard drives, enclosure management modules (EMMs), Field Replaceable
Unit (FRUs), and installed software. To view the details of hardware components in the storage sled:
1. From the Devices drop-down, select Storage.
2. Select a storage from the list of the storage devices.
3. On the right side, click View Details.
4. To view the hardware details, click Hardware. The hardware components in the storage sled are displayed at the top of the
Hardware page.
Viewing drive details
To view the list of drives in the storage sled, click Hardware > Hard Drives. You can assign a hard drive to a compute sleds.
NOTE: Use the iDRAC web interface to update the firmware for a drive.
60 Managing storage