To assign an enclosure:
1. From the Devices drop-down list, select Storage.
2. Select the storage sled from the list of the storage devices.
3. Click View Details.
The storage Overview page is displayed.
4. Click Hardware and select Enclosure-Assigned.
A warning message about loss of data while selecting this mode is displayed.
5. Select I understand that reseting this assignment could result in data loss and click Ok.
6. Select the compute sled slots and click Assign.
After replacing PERC card, wait for some time for OMEModular to get the new inventory details from iDRAC before
performing the assignment operation. Else, refresh the inventory on the Compute page, manually.
Replacing storage sleds
When you remove a storage sled from one slot and insert it into another slot on the chassis, the mapping on the new slot is used
for the storage sled. If you replace the storage sled with a new sled which does not have a service tag, the service tag and the
mapping of the sled that was present in the slot earlier, are applied. However, the storage sled firmware is not replaced
automatically.
Updating enclosure firmware
You can update or rollback the storage enclosure firmware using the OMEModular. Use the following methods to update the
firmware:
1. Dell Update Package (DUP)
2. Catalog-based compliance method
NOTE: The OMEModular is inaccessible during the update process.
Updating the firmware using DUP
1. Download the DUP from www.dell.com/support/drivers.
2. On the OMEModular web interface, go to Devices > Storage.
3. Select the storage sled on which you want to update the firmware.
4. Click Update Firmware.
5. Select the Individual package option and click Browse to go to the location where you have downloaded the DUP.
Wait for the comparison report, the supported components are displayed.
6. Select the required components and click Update to start the firmware update.
7. Go to the Monitoring > Jobs page to view the job status.
Updating the firmware using catalog-based compliance
1. On the OMEModular web interface, go to Devices > Storage.
2. Select the storage sled on which you want to update the firmware.
3. Click Update Firmware.
4. Select the baseline and click Next.
The Schedule Update page is displayed.
5. Select the Schedule Update options as required.
Update Nowapply the firmware updates immediately.
Schedule Laterschedule the firmware updates for a later date. Select the required date and time.
Server Optionschoose to apply the update as required.
62