Dell EMC OpenManage Enterprise Modular Edition Version 1.20.10 for PowerEdge MX7000 Chassis RACADM Command Line Reference Guide August 2020 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 -2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: Introduction................................................................................................................. 5 New in this release.............................................................................................................................................................. 5 Supported RACADM Interfaces.......................................................................................................................................
cfgDNSDomainName (Read or Write)................................................................................................................... 29 cfgDNSDomainNameFromDHCP (Read or Write).............................................................................................. 29 cfgStorageModule............................................................................................................................................................ 30 cfgStorageModuleStorageMode....................
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for Dell EMC OpenManage Enterprise Modular (OME – Modular). Topics: • • • • New in this release Supported RACADM Interfaces RACADM Command Options Other documents you may need New in this release ● Added the attribute, switch- to the command,connect to facilitate connection to I/O module serial consoles.
Table 1. Details of RACADM command options (continued) Option Description -u Specifies the user name that is used to authenticate the command transaction. If the -u option is used, the -p option must be used, and the -i option is not allowed. -p Specifies the password that is used to authenticate the command transaction. If the -p option is used, the -i option is not allowed. -S Specifies that RACADM should check for invalid certificate errors.
Table 3. List of documents (continued) Name of the document Brief introduction of the document Dell EMC PowerEdge MX7000 Enclosure Installation and Service Manual This document provides information about installing and replacing components in the PowerEdge MX7000 enclosure. Dell EMC PowerEdge MX5016s and MX5000s Installation and Service Manual This document provides information about installing and replacing components in the PowerEdge MX5016s storage sled and PowerEdge MX5000s SAS IOM.
2 RACADM sub command details This section provides detailed descriptions about the RACADM subcommands, including the syntax and valid entries.
● # (pound) ● ASCII code 32 (space) NOTE: The - (dash) character cannot be the first character of the string, regardless of whether the string is quoted. There are different escaping rules for double quotation marks. There are different escaping rules for using single quotation mark and double quotation marks.
? ? arp chassisaction config ...
Table 4. racadm arp (continued) Address HWtype HWaddress Flags Mask Iface 192.168.1.120 ether 90:b1:1c:f4:32:09 C pub 192.168.0.121 ether 90:b1:1c:f4:34:f4 C pub chassisaction Description Runs the turn on, turn off, power cycle, or reset operation. Synopsis Input racadm chassisaction [-m ] ● -m—Must be one of the following values: ○ chassis—Default state if -m is not specified.
Examples ● Executes on a leader, adds a stand-alone chassis to the group: racadm chassisgroup add -m 192.168.0.
● -b—The subcategory used to filter the records. Provide multiple subcategories using a "," as the delimiter. The value is case-insensitive.
cmcchangeover Description Changes the redundant state of the management module from active to standby and standby to active. Synopsis racadm cmcchangeover Input racadm cmcchangeover Example NA NOTE: During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power state is displayed after the inventory is refreshed. config Description Modifies the configuration properties of the management module.
Input ● -b—Binary mode If -b is used, reset OME-Modular to terminate the connect. ● -m—The option must be one of the following values: ○ server-—where n = 1-8 ○ switch-—where n = 1-6 CAUTION: When run from the OME–Modular serial console, the connect -b option stays connected until the management module resets or the serial console is terminated. This connection is a potential security risk.
Input ● -m——must be one of the following values: ○ server ○ switch ● -a—[server|switch]—applies options to all modules present in the chassis of the given module type; if specified must be one of the following values: ○ server ○ switch If the module type is not specified, the default type is server. NOTE: Switches must support Ethernet management. ● -u—The username for servers must be 'root'. ● -p—Password for the given username.
● Set SNMPv1 community string for switch-5 racadm deploy -m switch-5 -v SNMPv1 CommStrPart1,CommStrPart2,CommStrPart3 ro ● Set root password to "calvin" for all servers racadm deploy -a -u root -p calvin ● Set password for all switches racadm deploy -a switch -u root -p faultlist Description Displays the active error message in the chassis subsystem. Synopsis racadm faultlist view $ racadm faultlist view Example SubSystem = System.Modular.
● -o—Specifies the configuration object to display. This option is used with -g. ● -i—Specifies the index of indexed group. This option is used with -g. ● -m—The must have one of the following values: ○ storage-—Where n = 1 to 8 NOTE: The storage- option is available only for cfgStorageModule. ● -h—Displays all the available configuration groups.
getniccfg Description Displays the network settings for modules. Synopsis Input racadm getniccfg [-m ] -m—The must be one of the following values: ● chassis—Default state if -m is not specified. ● switch-—Where n = 1–6 Example ● Display switch network settings racadm getniccfg -m switch-1 ● Display chassis network settings racadm getniccfg -m chassis getpbinfo Description Synopsis Input Example Gets power budget status information.
Used Power in EPP Pool EPP Percent - Available = Not Applicable = Not Applicable [Chassis Power Supply Status Table]
Peak System Power Timestamp Minimum System Power Minimum System Power Start Time Minimum System Power Timestamp System Idle Power System Potential Power System Input Current Reading = = = = = = = 11:37:36 08/08/2018 606 W (2067 BTU/h) Not Applicable 10:16:08 08/06/2018 Not Applicable Not Applicable Not Applicable [Real-Time Energy Statistics] System Energy Consumption System Energy Consumption Start Time System Energy Consumption Timestamp = 204 kWh = Not Applicable = 05:47:05 08/20/2018 [System Power
FanSpeed rpm FanSpeed rpm FanSpeed rpm FanSpeed rpm FanSpeed rpm 5 N/A 6 N/A 7 N/A 8 N/A 9 N/A Temp Celsius 1 -7 PWR OK PWR Not OK PWR N/A PWR OK PWR Not OK PWR N/A ● N/A N/A N/A N/A N/A Fan-5 Fan-6 Fan-7 Fan-8 Fan-9 100 0 100 100 100 OK 14513 Not OK N/A OK 14510 OK 14479 OK 14484 Chassis Inlet Temperature 47 OK 27 1 PS-1 Online 2 PS-2 Input Lost 3 PS-3 Slot Empty 4 PS-4 Online 5 PS-5
Synopsis racadm getsysinfo [-d] [-c] [-4] [-6] Input ● ● ● ● ● ● Example ● Displays Chassis Information -d—Displays MM information -c—Displays chassis information -4—Displays IPv4 settings -6—Displays IPv6 settings -6 without -s option—Sets the static IPv6 address for the chassis -6 without -d option—Enables autoconfiguration of IPv6 for the chassis racadm getsysinfo -c ● Displays MM Information racadm getsysinfo -d ifconfig Description Synopsis Displays the network interface information.
racreset Description Resets the RAC. Synopsis racadm racreset racresetcfg Description Restores the RAC configuration to factory defaults. Before or after performing racresetcfg in the member chassis, go to the lead chassis and remove the member chassis from the MCM group. Synopsis Input racadm racresetcfg ● -f—Resets all management module configurations to the default configuration and preserves the user-configured and network settings.
Input ● -m—The must be server-, where n = 1 to 8 ● -a—Performs power action on all servers Example ● Power action on a single server: racadm serveraction -m server-1 powerdown ● Power action on all servers: racadm serveraction -a powerup ● Reseat action on a single storage: racadm serveraction -m storage-2 -f reseat setniccfg Description Synopsis Modifies network configuration properties.
● Configuration of chassis to a static IPv6 address: racadm setniccfg -m chassis -s -6 2001:DB8::2 64 2001:DB8::1 ● Configuration of VLAN id for chassis: racadm setniccfg -m chassis -v 1000 ● Removal of VLAN configuration from a chassis: racadm setniccfg -m chassis -v swinventory Description Synopsis Input Displays the list of the software objects installed in the chassis.
3 OpenManage Enterprise Modular property database group and object descriptions You can configure a setting that does not have a hash sign (#) prefixed in the output. To modify a configurable object, use the — o option. Topics: • • • • cfgLanNetworking cfgStorageModule cfgUserAdmin cfgRacTuning cfgLanNetworking This group contains parameters to configure OME-Modular NIC for IPv4. One instance of the group is allowed.
3. racadm config -g cfglannetworking -o cfgDNSServer1 100.69.112.5 For Alternate DNS Server name use cfgDNSServer2 4. racadm config -g cfglannetworking -o cfgDNSRegisterRac 1 If step 1 is applied, to return to the original state. NOTE: You can modify the cfgDNSServer1 and cfgDNSServer2 only when cfgDNSServersFromDHCP is 0. Else, the static DNS server settings are ignored. NOTE: Disable Use DHCP for DNS Domain Name to configure the DNS Domain Name.
Legal Values ● 1 — True ● 0 — False Default 0 NOTE: For IPv6, only the DHCPv6 address or static address is registered. Example: racadm getconfig -g cfgLanNetworking cfgDNSServersFromDHCP=1 cfgDNSServer1=192.168.0.5 cfgDNSServer2=192.168.0.6 cfgDNSRacName=cmc-frankly cfgDNSDomainName=fwad.lab cfgDNSDomainNameFromDHCP=1 cfgDNSRegisterRac=1 cfgDNSRacName (Read or Write) Description Displays the management module name, which is Service Tag by default.
Default 0 This property is used only if DHCP is enabled for the IPv4 stack or if IPv6 and IPV6 autoconfig are enabled. The management module can obtain its DNS domain name from either a DHCP or DHCPv6 server, if the following properties are set to 1 (true): ● ● ● ● IPv4Enable NIC Enabled IPv6 Enabled Autoconfiguration Enabled The network administrator must ensure that these DHCP servers are configured to provide the same DNS domain name to the management module.
cfgStorageModuleServiceTag Description Synopsis Input Example Displays the service tag. cfgStorageModuleServiceTag= cfgStorageModuleServiceTag= cfgStorageModuleServiceTag=MX0000 cfgStorageModuleAssetTag Description Synopsis Input Example Displays the asset tag. cfgStorageModuleAssetTag= cfgStorageModuleAssetTag cfgStorageModuleAssetTag=xxxxxx cfgConnectedSlots Description Synopsis Input Example Displays the connected slots.
cfgUserAdminPassword - Write Only Description The password for this user. User passwords are encrypted and cannot be seen or displayed after the property is written. Legal Values A string of up to 20 ASCII characters. The following characters are supported in a password: ● ● ● ● Default Uppercase letters Lowercase letters Numbers—0-9 Special characters—/, -, _, .