CLI Guide

Input
-bBinary mode
If -b is used, reset OME-Modular to terminate the connect.
-mThe <module> option must be one of the following values:
server-<n>where n = 1-8
switch-<n>where n = 1-6
CAUTION: When run from the OMEModular serial console, the connect -b option stays
connected until the management module resets or the serial console is terminated. This
connection is a potential security risk.
NOTE: The racadm connect to server prompts you to enter the iDRAC credentials for connecting
to the server.
Example
Connect to server 1 serial console:
racadm connect -m server-1
Connect to I/O module 1 serial console:
racadm connect -m switch-1
NOTE: When you run the racadm connect -m switch-<N> command for the first time, the
option to enter the user credentials is not displayed. Press Enter again to view the option to enter
the user credentials.
NOTE: Use quit key that is configured on the iDRAC to quit the console.
NOTE: When you run the command, racadm connect -m switch-<N>, the first time, the option to enter the user
credentials is not displayed. Press [Enter] again to view the option to enter the user credentials.
deploy
Description
Deploys blade or IOM by specifying required properties.
In the firmware or SSH racadm interface, enter a backward slash before the string. For example: xyz
\^123. In remote racadm, enter the string in double quotes. For example: "xyz^123".
NOTE: The quick deploy command is not supported in RACADM.
Synopsis
racadm deploy -m server-<n> -u root -p <password> -s <ipaddress>
<subnet> <gateway>
racadm deploy -m server-<n> -u root -p <password> -s -6 <ipv6Address>
<prefixlen> <gateway>
racadm deploy -m server-<n> -u root -p <password> -d [-6]
racadm deploy -m switch-<n> -u root -p <password>
racadm deploy -m switch-<n> -v SNMPv2 <snmpCommunityString> ro
racadm deploy -a [server|switch] -u root -p <password>
NOTE: For IOMs, you can only configure SNMPv2 community strings.
RACADM sub command details 15