CLI Guide

Set SNMPv1 community string for switch-5
racadm deploy -m switch-5 -v SNMPv1
CommStrPart1,CommStrPart2,CommStrPart3 ro
Set root password to "calvin" for all servers
racadm deploy -a -u root -p calvin
Set password for all switches
racadm deploy -a switch -u root -p <password>
faultlist
Description Displays the active error message in the chassis subsystem.
Synopsis
racadm faultlist view
$ racadm faultlist view
Example
SubSystem = System.Modular.7
Message = CPU 1 is absent
InstanceId = Fault#02200004#1
Severity = Critical
MessageId = CPU0003
SubSystem = PowerSupply
Message = The power input of power supply 1 is lost.
InstanceId = Fault#02200005#1
Severity = Critical
MessageId = PSU0003
SubSystem = PowerSupply
Message = The power input of power supply 5 is lost.
InstanceId = Fault#02200006#1
Severity = Critical
MessageId = PSU0005
getconfig
Description
Displays the configuration properties of OME-Modular.
Synopsis
racadm getconfig -g <group> [-m <module>]
racadm getconfig -g <group> -o <object> [-m <module>]
racadm getconfig -g <group> -i <index>
racadm getconfig -g <group> -o <object> -i <index>
racadm getconfig -h
Input
-gSpecifies the configuration group to display
RACADM sub command details 17