CLI Guide

Used Power in EPP Pool = Not Applicable
EPP Percent - Available = Not Applicable
[Chassis Power Supply Status Table]
<Name> <Model> <Power State> <Input Current>
<Input Volts> <Output Rated
Power>
PS1 PSU.Slot.1 Online 1.55 A 226
V 3000
W
PS2 PSU.Slot.2 Online 1.57 A 227
V 3000 W
PS3 PSU.Slot.3 Online 1.65 A 227
V 3000
W
PS4 PSU.Slot.4 Slot Empty N/A N/
A N/A
PS5 PSU.Slot.5 Slot Empty N/A N/
A N/
A
PS6 PSU.Slot.6 Slot Empty N/A N/
A
N/A
[Server Module Power Allocation Table]
<Slot#> <Server Name> <Power State> <Allocation>
<Priority> <Blade Type>
1 SLOT-1 ON 605
W 1 PowerEdge MX840c
2 Extension (1) N/A N/
A N/A N/A
3 SLOT-3 ON 792
W 1 PowerEdge MX840c
4 Extension (3) N/A N/
A N/A N/A
5 SLOT-5 ON 227
W 1 PowerEdge MX740c
6 SLOT-6 ON 228
W 1 PowerEdge MX740c
7 SLOT-7 ON 240
W 1 PowerEdge MX740c
8 SLOT-8 ON 622
W 1 PowerEdge MX740c
getpminfo
Description
Gets power management status information.
Synopsis
racadm getpminfo
Input
racadm getpminfo
Example
[Real-Time Power Statistics]
System Input Power = 616 W (2101 BTU/h)
Peak System Power = 628 W (2142 BTU/h)
Peak System Power Start Time = Not Applicable