Release Notes
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition for PowerEdge MX7000 Chassis Release Notes
- Release summary
- Compatibility
- New and enhanced features
- Fixes
- Important Notes
- Known issues
- Advanced Filter option not working in Audit Logs
- iDRAC SSO does not work in OME-Modular
- Inconsistent behavior in lead and member chassis sleds during slot deployment
- Configured local time not applied on lead chassis and member chassis after disabling NTP
- MAC identities displayed in RESERVED state
- Chassis alerts not received in Redfish event listener after management module failover task
- Redeployment of MCM profiles for all member chassis sleds fails when VLAN is modified in device-based deployment
- All member chassis passive module is getting rebooted when performing "racadm racreset" in lead chassis
- Limitations
- Installation
- Resources and support
- Contacting Dell EMC
Configured local time not applied on lead chassis and
member chassis after disabling NTP
Description When you clear the external NTP and change the local time, internal NTP is slow in identifying the correct
time source. As a result, the time is reverted.
Workaround Set the required time on the Application Settings > Network > Time Configuration page.
Systems affected All systems supported in this release
Tracking number 192713
MAC identities displayed in RESERVED state
Description MAC identities displayed in RESERVED state for some of the partitions after Slot Deployment is
performed using Attach and Apply Immediately operation.
Workaround Redeploy OME-Modular.
Systems affected All systems supported in this release
Tracking number 194347
Chassis alerts not received in Redfish event listener
after management module failover task
Description
After the first management module (MM) failover:
● POST subscribers do not receive alerts and telemetry events.
● Telemetry customizations are not effective but are not lost.
Workaround Perform a second MM failover task.
Systems affected All systems supported in this release
Tracking number 195224
Redeployment of MCM profiles for all member chassis
sleds fails when VLAN is modified in device-based
deployment
Description
Server Profile deployment with modified attributes is failing for member sleds when only VLAN
configuration is modified.
Workaround While modifying the VLAN configuration from the Edit Network page, select the Propagate VLAN
checkbox. Perform full redeployment of the profile.
Systems affected All systems supported in this release
Tracking number 195597