Users Guide

Troubleshooting
This section describes the tasks for troubleshooting and resolving issues using the OMEModular user interface.
Firmware update is failing
Storage assignment is failing
Management role of IOMs is downgraded
IOM health is downgraded
Drives on compute sled are not visible
Storage sleds cannot be applied to IOMs
Drives in OpenManage are not visible
iDRAC drive information does not match OpenManage drive information
The assignment mode of storage sled is unknown
Topics:
Storage
Unable to access OME-Modular using Chassis Direct
Troubleshooting lead chassis failure
Storage
This section describes the issues that are related to storage sleds and steps to resolve the issues.
Firmware update is failing
1. Firmware update may fail if one or more subcomponents fail to flash during the firmware update process.
2. If an IOM is downgraded owing to a chassis mismatch or faulty subcomponent, the firmware activation fails.
Storage assignment is failing
A storage assignment fails if:
1. The IOMs are currently downgraded.
2. There is only one IOM present.
3. Only one hot-swappable Expander is present on a storage sled.
SAS IOM status is downgraded
Both SAS IOMs are degraded if a:
1. Peer SAS IOM is detected but cannot be communicated with.
2. Firmware Mismatch is detected.
3. Chassis Mismatch is detected.
SAS IOM health is downgraded
The SAS IOM health is downgraded if:
1. One or more subcomponents are faulty.
2. A non-SAS IOM is detected.
17